Watts Chrome Monitor & Non-Monitored Faucet Installation - Watts Premier RO-Pure Installation, Operation And Maintenance Manual

Reverse osmosis (ro) water treatment system
Table of Contents

Advertisement

WATTS Premier Chrome Monitored & Non-Monitored
(Top Mount) Faucet Installation
Mounting Hole Size
Torque on Toggle Bolt
Gather and identify the faucet pieces.
Step 6
Remove faucet base & faucet spout from their respective
plastic bags. From above the sink, feed the faucet base,
tubing & toggle bolt down through the
the sink.
Align the faucet base so that the handle is on the
right side and the base is sitting fl ush on the sink top. Ensure
that the soft rubber gasket is uniformly positioned in between
the base and the top of the sink.
Step 7
Lift faucet base and remove the white paper from the gasket
and stick it to the top of the sink in the appropriate position for
the faucet base. Turn the handle down (towards you) to the
"ON" position to reveal the tightening screw (located where
the spout will be inserted). Using a phillips head screwdriver,
turn the screw clockwise until the toggle bolt secures the
faucet base snug onto the sink top, do not over torque toggle
bolt (5lb.in. max)
Step 8
Once the faucet base is securely fastened to the sink top,
insert the faucet spout into the faucet base until it is fully
seated. Turn the handle up (vertical) to the "OFF" position.
Completion of faucet installation (tubing connections) will be
Step 9
done later in this manual. Refer to the Black Tube Connection
(page 12), Red Tube Connection (page 13), and Blue Tube
Connection (page 12) sections of this manual.
If your faucet is equipped with the monitoring function please proceed to the next step,
otherwise please proceed to the next page.
Faucet Battery Installation
Step 10
Insert the battery drawer with the battery into the base of the faucet until it is fl ush.
NOTE: The + side of the battery faces up. The compartment drawer will not slide in if the battery is installed upside
down.
When the battery is fi rst installed, both the red and green lights will fl ash to indicate that both lights are functional. Thereafter,
it will fl ash green only when the faucet handle is turned to the "ON" position. When your system is ready to be serviced
(approximately six months) you will see the light fl ash red when the handle is turned to the "ON" position. Refer to the Six
Month Maintenance (page 14) section of this manual for fi lter replacement.
NOTE: If your water usage is high the red light may activate sooner than six months indicating the need for fi lter
replacement.
This faucet provides an electronic monitor that will tell you when it is time to replace the fi lters in your water
treatment device. The light indicator will be green for the life of the fi lter, turning red once the life of the fi lter has
been reached. This can occur after six months of use, or sooner for heavy water usage. To reset the electronic
monitor during replacement of fi lters, simply slide out the battery from the faucet and reinsert. The battery life is
expected to last one year, however, for heavy use the battery may need to be replaced sooner. For replacement,
look for battery number CR2354 (Watts p/n:116082) which is available at your local battery store or contact Watts
Premier at 800-752-5582. You can also order online at www.wattspremier.com.
Minimum
Maximum
1.00"
1.25"
5lb.in. (max)
1¼" mounting hole in
Page 8