SERVICING INSTRUCTIONS
ACCESS PANELS
TOP PANEL:
Remove top panel to access hot water tank, thermostat, heating
elements, brew circuit tubing, faucet valve and piping.
Top panel is held by two screws at the rear and a retaining lip at
the front.
FRONT PANEL:
Remove front panel to access timer, terminal block and solenoid.
Front panel is held by two screws at the bottom and a retaining
lip at the top.
SOLENOID DOOR:
Remove solenoid door to access solenoid and plumbing
connections.
Solenoid door is held by two screws and a retaining lip.
FRONT
PANEL
BUTTON
PLUG
Fig. 9 Access Panels
TOP
PANEL
TIMER
SOLENOID
DOOR
11
CAUTION:
SHOCK HAZARD
Opening access panels or
removing warmer plates on this
brew may expose uninsulated
electrical components.
Disconnect brewer from
electrical power before
removing any panel or warmer
plate.
IL1707