Control Voltage - GE JCKSO6 Technical Service Manual

27-in. and 30-in. wall ovens
Table of Contents

Advertisement

Control Voltage

Models ZEK938, ZET938, JK915, JT915, JCK915,
JCT915, and JT912
TERMINALS
VOLTAGE
L1-N
120 VAC ALL THE TIME
COM TO N
120 VAC ALL THE TIME
240 VAC ALL THE TIME
L1-L2
L1-BA, L1-BR,
240 VAC oven on, not calling for heat.
DLB relay K9 closed.
L1-CV
*LIGHT-L1
120 VOLTS when light is on.
COM TO MDL
120 VOLTS not locking or unlocking, door closed.
**L1-CF
120 VOLTS when oven door is closed, fan off.
Models JKP20, JCKP20, JKS06, and JCKS06
TERMINALS
VOLTAGE
L1A & B TO N
120 VAC ALL THE TIME
240 VOLTS when oven is calling
DLB TO BAKE
for heat (BAKE and BROIL relay
DLB TO BROIL
contacts closed).
*OVL1–OVL2
120 VAC when light is off.
AUX1–N
120 VAC locking or unlocking.
Models JKP48 and JTP48
TERMINALS
VOLTAGE
L1-N
120 VAC ALL THE TIME
N to COM, COM 0,C
120 VAC ALL THE TIME
240 VOLTS when oven is not
L1-1 & 2-BAKE 1 & 2
calling for heat (BAKE, CONV. ,
L1-1 & 2-BROIL 1 & 2
& BROIL relay contacts open).
L1-1 & 2 CONV 1 & 2
L1 to Con J6 Term, 1
120 VOLTS when light is on.
& 3
L1 TO MDL 1 & 2
120 VOLTS locking or unlocking
120 VOLTS when oven door is
L1-to CON J6 Term 5
L1 - to CON J6 Term 6
120 VOLTS when cooling fan is
closed and Conv. Bake, Conv.
& 6 (See Conv. Fan
not running, 0 VOLTS when
Roast not operating.
Assy.)
cooling fan is running.
Model JKP28
TERMINALS
VOLTAGE
L1 & B - N
L1A & B -N
120 VAC ALL THE TIME.
AUX1
120 VAC ALL THE TIME.
240 VOLTS when oven is not calling
DLB TO BAKE
for heat (BAKE and BROIL relay
DLB TO BROIL
contacts open).
*OVL2–L1
120 VAC when light is on.
AUX2–N
120 VAC locking or unlocking.
Model JKP28
TERMINALS
VOLTAGE
120 VAC ALL THE TIME
L1-N
120 VAC ALL THE TIME
AUX1
DLB TO BAKE
240 VOLTS when oven is not calling
for heat (BAKE and BROIL relay
DLB TO BROIL
contacts open).
J4 5 to 7
120 VAC when light is off.
AUX2 - N
120 VAC locking or unlocking.
Models ZEK958, ZET958, JK955, JT953, and JT955
TERMINALS
VOLTAGE
L1-N
120 VAC ALL THE TIME
N to COM, COM 0, C
120 VAC ALL THE TIME
L1-1 & 2-BAKE 1 & 2
240 VOLTS when oven is not
calling for heat (BAKE, CONV. ,
L1-1 & 2-BROIL 1 & 2
and BROIL relay contacts open).
L1-1 & 2 CONV 1 & 2
*L1 to Con J6 Term, 1 & 3
120 VOLTS when light is on.
120 VOLTS locking or unlocking.
L1 TO MDL 1 & 2
**L1-to CON J6 Term 5 &
120 VOLTS when oven door is
6 (See Conv. Fan Assy.)
closed and Conv. Bake, Conv.
Roast not operating.
Model JKP86
TERMINALS
VOLTAGE
120 VAC ALL THE TIME
L1 TO N
L1 TO BAKE
240 VOLTS when oven is not calling for heat
L1 TO BROIL
(BAKE and BROIL relay contacts open).
120 VAC when light is on.
*LAMP-L1
120 VAC not locking or unlocking, door closed.
MOTOR 1-MOTOR 2
Models ZEK958, ZET958, JK955, JT953, and JT955
TERMINALS
VOLTAGE
120 VAC ALL THE TIME
L1-N (CN01-1)
240 VOLTS when oven is not calling for heat
L1 TO BAKE
(BAKE and BROIL relay contacts open).
L1 TO BROIL
L1 TO CONVECT
*CNO1-2 TO L1
120 VAC when light is on.
120 VOLTS not locking or unlocking, door closed.
N TO CN01-4
120 VOLTS when oven door is closed, fan off.
L1 TO CN01-3
*If oven light is not working, make the following checks:
• Check oven light bulb.
• Light is to come on when the door is opened–check
voltage across light socket. Terminals should read 120
VAC. If 0 volts, check jamb switch and wiring.
• Light is to come on when control light pad is pressed.
K11 or K12 should click. Check voltage from N to J6-3
(upper) or N to J6-1 (lower). Should read 120 VAC. If 0
volts, check oven light keypad using Ohmeter Test. If
keypad is good, replace the control.
**If convection fan not running, make the following
checks:
• Check the voltage from terminal CN01-3 to N on
control–it should read 120 V in Conv. Bake or Roast
mode.
• If voltage OK, check convection fan motor. It should read
approx. 15-20 Ω at room temp. Check to make sure the
fan shaft is not rubbing on the oven liner.
• Check Door Switch.
– 21 –