2.5
DO NOT operate the appliance if: (in all cases turn off mains power and isolate
water supply)
1. Water ceases to flow during use.
2. Water has entered inside the unit because of an incorrectly fitted cover.
3. If the appliance is damaged.
2.6
ISOLATE the electrical and water supplies before removing the cover.
2.7
ISOLATE the electrical and water supplies BEFORE proceeding with
installation or servicing.
2.8
The product is NOT SUITABLE for mounting into steam rooms or
steam cubicles.
2.9
The installation must be carried out in accordance with the relevant
requirements of:
• The appropriate Building Regulations either The Building Regulations,
The Building Regulations (Scotland) or Building Regulations (Northern
Ireland).
• The Water Fittings Regulations or Water Byelaws in Scotland.
• The IEE Wiring Regulations - BS7671.
CAUTION
2.10 It is recommended that persons who may have difficulty understanding
or operating the controls should not be left unattended whilst using appliance.
Special consideration should be given to young children and persons with
reduced physical, sensory or mental capabilities.
2.11 Only use designated entry points for cable and pipe.
PLUMBING
2.12 The plumbing installation must comply with Water Regulations.
2.13 The supply pipe must be flushed to clear debris.
2.14 DO NOT solder pipes or fittings within 300mm once the pipe work is
located in the appliance, as heat transfer can damage components.
2.15 All plumbing connections must be completed and checked for leaks before
making the electrical connections.
ELECTRICAL
2.16 Before fitting the appliance, ensure that the consumer unit and any
switches are suitable for the additional load. If in doubt, contact your
electricity supplier or a qualified electrician.
2.17 The installation must comply with the latest BS 7671 'Requirements for
Electrical Installations' (IEE Wiring Regulations).
2.18 This appliance must be earthed.
2.19 A residual current device (rcd), formerly known as an earth leakage circuit
breaker (elcb), with a tripping current of 30mA must be incorporated in the
circuit.