Xycom 5019T User Manual

Flat panel industrial touch monitor

Advertisement

Quick Links

5019T
Flat Panel Industrial Touch Monitor

User Manual

© © © © 2004 XYCOM AUTOMATION, INC.
Printed in the United States of America

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5019T and is the answer not in the manual?

Questions and answers

Summary of Contents for Xycom 5019T

  • Page 1: User Manual

    5019T Flat Panel Industrial Touch Monitor User Manual © © © © 2004 XYCOM AUTOMATION, INC. Printed in the United States of America...
  • Page 2 This document is copyrighted by Xycom Automation Incorporated (Xycom Automation) and shall not be reproduced or copied without expressed written authorization from Xycom Automation. The information contained within this document is subject to change without notice. Xycom Automation does not guarantee the accuracy of the information.
  • Page 3: Table Of Contents

    ..............................5 NPACKING THE ................................5 UICK TARTUP CHAPTER 2 – INSTALLATION.............................6 ...............................6 NSTALLATION VERVIEW ..............................8 RODUCT IMENSIONS 5019T Dimensions ..............................8 ..............................9 OWER ANAGEMENT System Power................................9 Excessive Heat ..............................10 Electrical Noise ..............................11 Line Voltage Variation ............................11 ........................12 AZARDOUS OCATIONS NSTALLATIONS Definitions ................................13 Power Switch ...............................15...
  • Page 4: Chapter 1 - Introduction

    Xycom Automation industrial flat panel touch monitors offer state-of-the-art performance and features while meeting the rigorous requirements of the plant floor. Xycom’s 5019T high-resolution flat panel display is contained within a rugged housing with a resistive membrane touch screen. Standard Features •...
  • Page 5: Front Panel Controls

    5019T Flat Panel Industrial Touch Monitor Chapter 2 – Installation Front Panel Controls Figure 1-1. 5019T Front Panel Controls Table 1-1. 5019T Front Panel Controls Functions Feature Description Menu This button is used to open and select options in the On Screen Display (OSD) menu.
  • Page 6: I/O Panel

    Used to enable or disable (lock) adjustment buttons on front of monitor Video Inputs The 5019T monitor has four video input options: Digital Video Input (DVI), a DVI-D connector, for digital signal input to an analog monitor; VGA Input (VGA), to connect this VGA monitor for standard analog input from a computer;...
  • Page 7: Unpacking The Unit

    5019T Flat Panel Industrial Touch Monitor Chapter 2 – Installation Unpacking the Unit When you remove the 5019T from its shipping box, verify that you have the parts listed below. Save the box and inner wrapping in case you need to reship the unit.
  • Page 8: Chapter 2 - Installation

    5019 and connect the other end of the cable to the Protective Earth ground. 7. Turn on power to the 5019T unit. Then turn on power to the host computer. The system will boot up into the operating system.
  • Page 9 5019T Flat Panel Industrial Touch Monitor Chapter 2 – Installation Additional aspects to take into account when mounting your 5019T unit: Consider locations of accessories such as AC power outlets and lighting • • • • (interior lighting and windows) for installation and maintenance...
  • Page 10: Product Dimensions

    5019T Flat Panel Industrial Touch Monitor Chapter 2 – Installation Product Dimensions 5019T Dimensions Note: All dimensions are in inches. Figure 2-1. 5019T Dimensions 143627(A)
  • Page 11: Power Management

    5019T Flat Panel Industrial Touch Monitor Chapter 2 – Installation Power Management The monitor is based on the VESA DPMS and the DVI DMPM standards. To activate the monitor's Power Management function, both the video controller and the computer must conform to the VESA DPMS standard and the DVI DMPM standard.
  • Page 12: Excessive Heat

    – DC Return Input Protective Earth Ground Caution: Use AWG18 wire or greater for the 5019T’s power cable. Isolate the AC main circuit line, I/O signal lines, and power cord - do not bind or group them together. Excessive Heat...
  • Page 13: Electrical Noise

    5019T Flat Panel Industrial Touch Monitor Chapter 2 – Installation Electrical Noise Electrical noise is seldom responsible for damaging components, unless extremely high energy or high voltage levels are present. However, noise can cause temporary malfunctions that can result in hazardous machine operation in certain applications.
  • Page 14: Hazardous Locations Installations

    5019T Flat Panel Industrial Touch Monitor Chapter 2 – Installation Hazardous Locations Installations Xycom Automation designed the 5019T monitor with the intention of meeting the requirements of Class I, Division 2 Hazardous Locations applications. Division 2 locations are those locations that are normally non-hazardous, but potentially hazardous should an accident expose the area to flammable vapors, gases or combustible dusts.
  • Page 15: Definitions

    5019T Flat Panel Industrial Touch Monitor Chapter 2 – Installation Advertissement Risque D’ Explosion Avant de deconnecter l’equipment, coupler le courant ou s’assurer que l’emplacement est designe non dangereux. Warning - Explosion Hazard When in hazardous locations, turn off power before replacing or wiring modules.
  • Page 16: Division 1 Locations

    Combustible dusts of an electrically conductive nature may be present in • • • • hazardous quantities. Note Xycom Automation 5019T, 5019T-24V systems are not suitable for installation within Division 1 locations. Note Electrical equipment cannot be installed in Division 1 locations unless...
  • Page 17: Power Switch

    5019T Flat Panel Industrial Touch Monitor Chapter 2 – Installation Groups All electrical equipment that is approved for use in hazardous locations must include a group rating. Various flammable and combustible substances are divided into these groups as a function of their individual maximum experimental safe gap (MESG), explosion pressure, and ignition temperature.
  • Page 18: Operation And Maintenance

    Always observe the following rules with respect to hazardous location installations: 1. Always install the 5019T monitor within an enclosure suitable for the specific application. General-purpose enclosures may be acceptable for Class I applications but are never acceptable for Class II applications.
  • Page 19: Safety Agency Approval

    Information Technology Equipment • EN 60950, Information Technology Equipment Mounting Options The 5019T can be mounted in a panel or to an arm. The following sections describe the two mounting options. Panel Installation The 5019T monitor should be mounted and used where NEMA 4 and NEMA 12 type enclosures are employed.
  • Page 20 Chapter 2 – Installation Figure 2-2. 5019T Cutout Dimensions The 5019T has 16 total mounting clips: 4 mounting clips each on the top, bottom and both of the sides of the monitor. Hold the monitor in place while you install the mounting clips (see Figure 2-3 for mounting clip locations).
  • Page 21: Vesa Arm Mounting

    Figure 2-5 gives the dimensions for arm mounting. Please note that there are 3 sets of mounting holes on the back of the 5019T monitor: one for mounting the monitor on a 100 mm VESA arm; one for attaching a Xycom Automation 1506 Node PC to the monitor;...
  • Page 22: Chapter 3 - Monitor Settings

    With the OSD enabled, follow the general instructions below to navigate through the adjustment menus and make adjustments. Note If your 5019T monitor has a stainless steel bezel, the OSD controls will be located on the back of the unit. 143627(A)
  • Page 23 5019T Flat Panel Industrial Touch Monitor Chapter 3 – Monitor Settings Figure 3-1. Front Panel Control Buttons Press MENU to view the onscreen adjustment menus. Use UP, DOWN, , or to highlight one of the following adjustment menus: Picture in Picture...
  • Page 24 5019T Flat Panel Industrial Touch Monitor Chapter 3 – Monitor Settings must page through all of the adjustment menus to reach the Exit menu. Press - or + to exit the OSD adjustment menus. See Figure 3-2 through Figure 3-7 for snapshots of the adjustment menus and their respective adjustment options.
  • Page 25 5019T Flat Panel Industrial Touch Monitor Chapter 3 – Monitor Settings Figure 3-4. OSD Adjustment Menus (Picture in Picture, Video Scaling) Figure 3-5. OSD Adjustment Menus (Graphic Scaling Modes, Language, Video Source) 143627(A)
  • Page 26 5019T Flat Panel Industrial Touch Monitor Chapter 3 – Monitor Settings Figure 3-6. OSD Adjustment Menus (Utilities) Figure 3-7. OSD Adjustment Menus (Volume, Exit Menu) 143627(A)
  • Page 27: Reset Factory Default Settings

    H sync signal input: TTL level, negative true or positive true • V sync signal input: TTL level, negative true or positive true Video Modes The following video modes are supported on the 5019T flat panel SVGA monitor : 1280 x 1042 • • • •...
  • Page 28: Chapter 4 - Operator Input

    Chapter 4 – Operator Input Installing the Touch Screen Driver Follow these steps to install the touch screen driver. 1. Insert the Xycom Automation Documentation and Support CD in the CD- ROM. 2. Navigate to the \DRIVERS\TOUCHSCREEN\ELO.zip file. 3. Unzip the files and run setup.exe from the folder for the operating system running on your system.
  • Page 29: Accessing The "Mouse Right Button" Functionality With The Touch Screen

    5019T Flat Panel Industrial Touch Monitor Chapter 4 – Operator Input Note The touch screen and controller are a matched pair calibrated at the factory. If touch screen and controllers are interchanged calibration may be needed. Accessing the “Mouse Right Button” Functionality with the...
  • Page 30: Chapter 5 - Hardware

    Chapter 5 – Hardware The following sections outline the hardware included in your 5019T monitor. VGA Input Connector The VGA input connector is a D-sub connector with 15 pins. Table 5-1. VGA Input Connector Pinout Signal Name Green Blue Reserved (GND)
  • Page 31: Dvi-D Input Connector

    5019T Flat Panel Industrial Touch Monitor Chapter 5 – Hardware DVI-D Input Connector The DVI-D Input Connector is a D-sub connector with 26 pins (P3). Table 5-2. DVI-D Input Connector Pinout Signal Name Signal Name TMDS Data 2- TMDS Data 2+...
  • Page 32: Touch Screen Rs-232 Output Connector

    Note Since all serial interface signals are the same on the PC side, use a straight cable to connect the 5019T to the PC. Touch Screen USB Output Connector The Touch screen USB output connector is a B-style female USB connector.
  • Page 33: Hardware Specifications

    Appendix A – Technical Specifications The following tables outline the hardware and environmental specifications for the 5019T Flat Panel Industrial Touch Monitor. Hardware Specifications The following table lists the hardware specifications for the 5019T. Table A - 1. 5019T Hardware Specifications Characteristic Specification...
  • Page 34: Appendix A - Technical Specifications

    5019T Flat Panel Industrial Touch Monitor Appendix A – Technical Specifications Environmental Specifications The following table outlines the environmental specifications for the 5019T. Table A - 2. 5019T Environmental Specifications Characteristic Specification Temperature Operating 0° to 50° C (32° to 122° F) Non-operating -20°...
  • Page 35 This site contains the newest product datasheets, references by industrial sector, application notes, and a link to email technical support (support@xycom.com). You can also reach Xycom Automation Technical Support by phone or fax: Phone: 734-944-0482 Fax: 734-429-1010, Attention – Technical Support...
  • Page 36: Appendix B - Technical Support

    Xycom Automation’s Product Repair & Customization Department (PR&C) restores equipment to normal operating condition and implements engineering changes that enhance operating specifications. Xycom Automation tests products returned to Xycom with the standard Xycom test diagnostics. Follow the steps below to prepare the unit for shipment: 1.
  • Page 37 Index Controls Mounting Dimensions Front panel, 2 Panel Cutout, 16 Definitions Mounting Dimensions Hazardous Locations, 12 VESA Arm, 18 Electrical Noise, 10 Mounting Options, 16 Excessive Heat, 9 OSD Switch, 19 Features Pinout Optional, 1 DVI-D Input Connector, 28 Standard, 1 Serial Signal Input Connector, 29 Front panel controls, 2 Touch Screen USB Output, 29...
  • Page 38 143627(A) Xycom Automation, Inc. Canada Sales: 905-607-3400 734-429-4971 Northern Europe Sales: +44-1604-790-767 Fax: 734-429-1010 Southern Europe Sales: +39-011-770-53-11 http://www.xycom.com...

Table of Contents