Mira Azora Installation & User Manual page 20

Thermostatic electric shower
Table of Contents

Advertisement

Symptom
Start/
Stop.
Light
L o w o r n o
ON
flow.
ON
ON
ON
OFF
ON
ON
Operation of
ON
t e m p e r a t u r e
c o n t r o l h a s
ON
l i t t l e o r n o
effect on water
ON
temperature.
ON
No change in
ON
t e m p e r a t u r e
between I/II/III
settings.
ON
Heater.
Probable.Cause
Setting.
I/II/III
Any
Water supply pipework or inlet
filter restricted by a blockage or
partial blockage.
Any
In su ffi ci e n t wa te r su p pl y
pressure/flow for operation.
Any
Other outlets (e.g. toilet, garden
hose, washing machine, etc.)
drawing water while the shower
is being used.
Any
Handset blocked.
Any
Service tunnel or cover not
fitted correctly causing Start/
Stop button not to operate.
Any
Inlet Valve faulty.
Any
H e a t e r Ta n k e x c e s s i v e l y
scaled.
II/III
Handset or inlet filter blocked.
II/III
Inlet valve faulty.
II/III
Heater tank failure.
II/III
Microswitch failure.
Any
I n s u ff i c i e n t m a i n s w a t e r
pressure.
Any
Possible failure of flow valve,
microswitch or heater tank.
0
Possible.Remedy
Flush supply pipe. Clean inlet
filter.
Contact local water company.
Supply pressure must be a
minimum of 0.7 bar. Note: If
other appliances are operating,
pressure may drop below 0.7
bar.
Turn off other appliances whilst
shower is in use.
Remove and clean.
Check case inserts are cut and
fitted correctly. Check services
(electrical or plumbing) are
not interfering with location of
service tunnel or cover.
Replace.
Replace. In hard water areas
consider the use of a water
softener.
Remove and clean.
Replace.
Replace.
Replace.
Contact local water company.
Check the continuity of the
microswitch or heater tank and
replace parts as necessary.