Ferroli OPTIMAX HE PLUS 25 S Instructions For Use, Installation And Maintenance page 21

Wall-mounted gas fired, pre-mix condensing system boiler
Table of Contents

Advertisement

OPTIMAX HE PLUS 25 S
Minimum Dimensions of Flue Terminal Positions
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
NOTE
N/A = Not applicable
In addition, the terminal should not be nearer than 150mm (fanned draught) to an
opening in the building fabric formed for the purpose
of accommodating a built-in element such as a window frame.
Condensing Terminal Positions: If the flue is to be terminated at low level, then the
potential effect of the plume must be considered.
The plume should not be directed:
Directly below an opening, air brick,
opening windows, etc.
Above an opening, air brick,
opening windows, etc.
Horizontally to an opening, air brick,
opening windows, etc.
Below gutters, soil pipes or drain pipes
Below eaves
Below balconies or car port roof
From a vertical drain pipe or soil pipe
From an internal or external corner
Above ground roof or balcony level
From a surface facing the terminal
From a terminal facing the terminal
From an opening in the car port (e.g. door,
window) into the dwelling
Vertically from a terminal on the same wall
Horizontally from a terminal on the same wall
From the wall on which the terminal is mounted
From a vertical structure on the roof
Above intersection with roof
Cod. 3540R540 - 02/2009 (Rev. 00)
across a frequently used access route
towards a window or door
across a neighbouring property
300mm
300mm
300mm
75mm
200mm
200mm
150mm
100mm
300mm
600mm
1200mm
1200mm
1500mm
300mm
N/A
150mm
300mm
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Optimax he 25 s

Table of Contents