B. Strain Relief Required; C. If Frame Grounding Is Allowed; D. 4-Wire Electrical Connections - Maytag 30" EYE-LEVEL MICROWAVE RANGE 30" EYE-LEVEL RANGE Installation Instructions Manual

30" eye-level microwave range and 30" eye-level range
Table of Contents

Advertisement

B. Strain relief required
LOCKING
,
II
INSERT FROM
UNDER FRAME
Disconnect clamping ring from strain relief. Push relief
(from bottom) through
hole beneath terminal
block.
Tighten clamping
ring (from above) onto strain relief
threads.
W-m
_--,.- is* ~l--T-i+..4 ,_.~.,,. --L-n-U
-I--Y.-w-
RUN CORD THROUGH
STRAIN RELIEF
Run cord or cable through strain relief.
Leave enough slack to attach ring-type terminals
to
terminal block. Tighten clamping
screws.
C. If frame grounding is allowed
SILVER COLORED
NEUTliAIv
1 ' '
Use this wiring
method ONLY if local codes permit
connecting
frame grounding
conductor
to neutral
wire of power cord.
THIS
APPLIANCE
IS MANUFACTURED
WITH
NEUTRAL
TERMINAL
CONNECTED
TO
THE
FRAME.
If local codes do not permit grounding
through
the
neutral.
The 3-conductor
cord or cable assembly
must
be replaced
by a 4-conductor
cord.
The
replacement
cord
must
be rated
240 volts,
50
amperes
and investigated
for use with ranges.
1.
2.
3.
4.
Connect
neutral wire to the center silver-colored
terminal.
Connect remaining 2 wires to the terminals on either
side of the silver colored terminal.
Use ring type terminals only. Connect with the brass
nuts that are taped to the frame. Do not loosen fac-
tory installed
nuts already on the terminal.
Replace terminal block cover.
D. 4-wire electrical connections
SILVER COLORED.
TERMINAL
i
y
I"'
RELIEF
:
Use this wiring
method
for mobile
homes and
whenever
a 4-wire installation
is required.
1. Remove the grounding
strap screw from the range
frame. Keep this ground screw. Bend up the ground-
ing strap so that it does not contact the range frame.
2. Connect the green ground wire to the frame of the
appliance with the ground screw, using the hole in
the frame where the ground strap was removed.
3. Connect the white neutral wire of the power cord to
the silver colored terminal of the terminal block. Con-
nect the remaining
wires to the outer terminals.
4. Replace the terminal block cover.