1 1 0
110V 60Hz
S
P 21
110V 60Hz
S
00
110V 60Hz
S
P 22
110V 60Hz
S
MAINTENANCE INSTRUCTIONS
21 – I
P
ARAMETER
I
GNITION POINT IN
6. Use buttons '+' o '-' to modify the value of the parameter
between: min = value of parameter 17; max = value of
parameter 18.
The default value is:
- 90 Hz for Natural Gas;
- 110 Hz for L.P.G.;
7. Press and release button 'S' to confirm. The parameter
number (21) will appear in the display.
8. Switch off the appliance and switch it back on again to
render the new parameter operative.
22 – F
P
ARAMETER
6. Use buttons '+' o '-' to modify the value of the parameter:
- 00 = Off
- 01 = On
If parameter value 01 is selected, during the appliance
operation, the display will show the fan frequency value for 10
min.
7. Press and release button 'S' to confirm. The parameter
number (22) will appear in the display.
8. Switch off the appliance and switch it back on again to
render the new parameter operative.
S
S
GNITION
EQUENCE
ETTING
H
Z
F
AN
REQUENCY VALUE DISPLAY