York YHJF18 Technical Manual page 3

Lx series split-system heat pumps 14.5 seer – r-410a – 1 phase 1.5 thru 5 nominal tons
Hide thumbs Also See for YHJF18:

Advertisement

Outdoor Unit
1,2
Required Orifice or TXV
3,4,5
Indoor Unit
AHE24B
AHE30B
AHE36C
AHE42D
AHE48D
AHE60D
AHR24B
AHR36B
AHR42C
AHR48D
AHR60D
AHV24B
AHV30B
AHV36C
AHV42D
AHV48D
AHV60D
AV*36
AV*48
FC/MC/PC32
FC/MC/PC35
FC/MC/PC37
FC/MC/PC43
FC/MC/PC48
FC/MC/PC60
FC/MC62
FC64
UC48
UC60
Some of the combinations shown in the above System Charge table require Advanced Main Air Circulating Fan indoor product. For approved coil
only matches, please see the "COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils" table.
FOOTNOTES:
1. For applications requiring a TXV use S1-1TVM*** series kit.
2. Approved orifice(s) shipped with outdoor unit.
3. Systems matched with furnaces or air handlers not equipped with blower-off delays may require blower Time Delay Kit S1-2FD06700224.
4. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
5. Refer to Cooling and Heating Performance Data tables for actual performance for specified system matches.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the outdoor unit, the smallest matched indoor unit, and 15 feet of interconnecting line tubing.
2. Verify the TXV or orifice and additional charge required for specific matched indoor unit in the system using the above table.
3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.
4. For indoor matches requiring additional charge, the refrigerant needs to be weighed in for specific matched indoor unit and lineset length.
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + charge adder for matched indoor unit +
charge adder for line set.
Johnson Controls Unitary Products
System Charge for Various Matched Systems
YHJF18S41S1 YHJF24S41S1 YHJF30S41S1 YHJF36S41S4 YHJF42S41S2 YHJF48S41S1 YHJF60S41S1
.051/4F1
.059/4G1
.051 / TXV + 0 .059 / TXV + 0
.051 / TXV + 0 .059 / TXV + 0
.051 / TXV + 0 .059 / TXV + 0
.051 / TXV + 0 .059 / TXV + 0
.051 / TXV + 0 .059 / TXV + 0
.051 / TXV + 13 .059 / TXV + 12 .063 / TXV + 0 .071 / TXV + 0
.051 / TXV + 13 .059 / TXV + 12 .063 / TXV + 0 .071 / TXV + 0
.051 / TXV + 0 .059 / TXV + 0
.051 / TXV + 0 .059 / TXV + 0
.051 / TXV + 13 .059 / TXV + 12 .063 / TXV + 0 .071 / TXV + 0
.051 / TXV + 13 .059 / TXV + 12 .063 / TXV + 0 .071 / TXV + 0
.063/4G1
.071/4H1
Additional Charge, Oz
.063 / TXV + 0 .071 / TXV + 0
.071 / TXV + 5 .073 / TXV - 10
.071 / TXV + 25 .073 / TXV - 6
.063 / TXV + 0 .071 / TXV + 0
.071 / TXV + 5 .073 / TXV - 10
.071 / TXV + 11
.071 / TXV + 31 .073 / TXV - 6
.071 / TXV + 25
.071 / TXV + 5 .073 / TXV - 10
.071 / TXV + 25 .073 / TXV - 6
.071 / TXV + 23
.071 / TXV + 38
561923-YTG-E-0613
.073, .075/4J1
4K1
.075 / TXV + 0
TXV + 0
.073 / TXV - 6
.075 / TXV + 0
TXV + 0
.075 / TXV + 0
TXV + 0
.075 / TXV + 0
TXV + 0
TXV + 8
4K1
TXV + 0
TXV + 0
TXV + 0
TXV + 8
3