York YHJF18 Technical Manual page 14

Lx series split-system heat pumps 14.5 seer – r-410a – 1 phase 1.5 thru 5 nominal tons
Hide thumbs Also See for YHJF18:

Advertisement

561923-YTG-E-0613
HEATING CAPACITY - Upflow, Downflow, and Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT
MODEL*
YHJF18S41S1
YHJF24S41S1
YHJF30S41S1
YHJF36S41S4
YHJF42S41S2
YHJF48S41S1
1. Rated CFM same as for cooling.
2. Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping
and no supplemental electric heat operation.
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input
during the same period.
MA Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS ,TG9S, use Coil Only Ratings.
— = Not Applicable.
HEATING CAPACITY - With Upflow, Downflow, & Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT
MODEL*
YHJF60S41S1
1. Rated CFM same as for cooling.
2. Heating MBH based on AHRI standards of 70° DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping
and no supplemental electric heat operation.
* Notates "Hot Heat Pump" performance. These ratings are not AHRI Listed.
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input
during the same period.
MA Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
— = Not Applicable.
14
1
COIL
MODEL
MBH
14.5 SEER HP COIL ONLY RATINGS
FC/MC/PC32
18.0
FC/MC/PC35
18.0
FC/MC/PC37
18.0
FC/MC/PC43
18.0
FC/MC/PC32
22.8
FC/MC/PC35
22.6
FC/MC/PC37
22.8
FC/MC/PC43
22.8
FC/MC/PC37
30.0
FC/MC/PC43
30.0
FC/MC/PC37
35.0
FC/MC/PC43
35.0
FC/MC/PC48
34.8
FC/MC/PC60
35.4
UC48
36.0
UC60
36.0
FC/MC/PC48
39.0
FC/MC/PC60
39.5
FC/MC62
39.0
FC/MC62
48.0
1
COIL
MODEL
STAGE
14.5 SEER HP COIL ONLY RATINGS
1
FC/MC62
2
2*
HEATING
47 F
COP
KW
MBH
3.56
1.52
11.4
3.52
1.56
11.3
3.62
1.50
11.3
3.62
1.50
11.3
3.40
1.96
14.2
3.38
1.99
15.4
3.40
1.96
14.2
3.40
1.96
14.2
3.72
2.43
19.3
3.70
2.43
19.4
3.52
2.91
20.8
3.52
2.91
20.8
3.52
2.90
20.8
3.64
2.85
21.2
3.70
2.85
21.4
3.68
2.87
20.8
3.64
3.14
26.8
3.78
3.06
29.4
3.74
3.09
25.0
3.66
4.12
32.6
HEATING
NET MBH
RATED
CFM
47 OD
1350
43.5
1800
60
1350
57
2
17 F
COP
KW
2.34
1.43
2.34
1.45
2.40
1.38
2.40
1.38
2.26
1.84
2.26
1.86
2.26
1.84
2.26
1.84
2.48
2.28
2.58
2.22
2.58
2.36
2.58
2.36
2.60
2.34
2.66
2.34
2.66
2.36
2.60
2.34
2.54
3.09
2.82
3.05
2.44
3.05
2.50
3.86
2
HSPF
17 OD
40.5
8.4
40.0
8.6
Johnson Controls Unitary Products
HSPF
STD
7.75
7.70
7.75
7.75
7.75
7.70
7.75
7.75
8.00
8.00
8.20
8.20
8.20
8.20
7.80
7.80
8.20
8.20
8.00
8.00
COP @ 47
3.42
3.58
3.36