Floor Protector - Lexington Forge SSW30FTAL Owner's Manual

Epa approved high efficiency air tight wood stove for residential installation 6" (152mm) flue required
Table of Contents

Advertisement

Do not connect the heater to any air distribution duct or system.
In Canada: The Canadian Standards Association has established different guidelines. Figure 11 shows one method, in which all
combustible material in the wall is cut away to provide the required 18
must remain empty.
A fl ush mounted sheet metal cover may be used on one side only. If covers must be used on both sides, each cover must be mounted
on non-combustible spacers at least 1
provide details of other approved methods of passing a chimney connector through a combustible wall. In Canada, this type of
installation must conform to CAN/CSA-B365. Installation Code for Solid Fuel Burning Appliances and Equipment.
NOTE: Do not vent your stove into a factory-built (zero-clearance) fi replace. These appliances and their chimneys are specifi cally
designed as a unit for use as fi replaces. It may void the listing or be hazardous to adapt them for any other use.

FLOOR PROTECTOR

Installation on a Concrete Floor
An appliance mounted on a concrete fl oor does not require fl oor protection.
Carpeting and any other combustible material shall not cover the fl oor protector.
If a combustible surface is applied to the concrete fl oor, a clearance must be maintained equivalent to the area reserved for the fl oor
protector. See Figure 12.
Installation on a Combustible Floor
If the appliance is to be installed on a combustible fl oor or a combustible fl oor covering, it must be installed on a 3/8
non-combustible millboard fl oor protector or durable equivalent. The pad must be installed beneath the appliance extending 18
"
mm) in Canada, 16
(406mm) in the U.S. on any side equipped with a door, and 8
must cover any horizontal chimney connector runs and extend 2
2" (51MM)
WALL LINE
8" (203MM)
8" (203MM)
63D0001
"
(25mm) clear of the wall. Your Lexington Forge dealer or your local building inspector can
2" (51MM)
18" (457MM)
DOOR SIDE OF
16" (406MM)
APPLIANCE
CANADA
U.S.A.
Figure 12: Installation on a combustible fl oor
"
(450 mm) clearance for the connector. The resulting space
"
(203mm) on all other sides. In the U.S. the pad
"
(51mm) beyond each side.
FLOOR
PROTECTOR
8" (203MM)
INSTALLATION
"
(10mm) thick
"
(457
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ssw30stalSsw30ftapbSsw30stapbSsw30ftpb