Download Print this page

Polygroup RP TYPE Owner's Manual page 2

Rp series swimming pool filter system for above ground swimming pools

Advertisement

4. The RP Type pump/filter systems are manufactured by Polygroup and ETL control number 4000608 - double
insulated and grounded - 115 V.A.C. - 60 Hz. (ALL Units must have a minimum of 105 V.A.C. to start and run
properly.)
Pump System
RP600 Filter System with F600C Pump
RP800 Filter System with F700C Pump
RP1000 Filter System with F1000C Pump
RP1000 Filter System with F1500C Pump
RP2000 Filter System with F2000C Pump
11
THE FILTER CARTRIDGE (15) WILL HOLD 1"
DIAMETER CHLORINE TABLETS. CHECK
LIBERALLY
YOUR CHLORINE LEVELS TO DETERMINE
LUBRICATE
10
THE PROPER NUMBER OF TABLETS TO ADD.
THE O-RINGS
(17,22,23,24 &26)
WITH SOME
PETROLEUM
JELLY
23
9
15
29
PATENTED
FILTER
CARTRIDGE
27
28
SYSTEM #7,005,062
24
24
22
19
7
14
13
4 Ea.
14
12
4 Ea.
8
Volute Housing
1-6
FIG. 1
Should you encounter any problems, contact the Customer Service at (888) 919-0070.
Extended operating days and hours during peak season requirements.
Wattage
Amperage
Flow Rate
46 watts
0.8 amps
580 G.P.H.
57 watts
1.1 amps
780 G.P.H.
80 watts
2.2 amps
1075 G.P.H.
120 watts
2.2 amps
1500 G.P.H.
2.2 amps
2000 G.P.H.
210 watts
*GPH - Gallons Per Hour
KEY
DESCRIPTION
1-6
MOTOR PUMP
7
PUMP RETAINING NUT
8
FILTER CASE
9
SEAL TOP
10
SEAL TOP RETAINER
11
VENT SCREW
12
SUCTION HOSE
13
RETURN HOSE
14
HOSE CLAMPS
15
FILTER CARTRIDGE
16
SUCTION FITTING (SF)
17
SF GASKET (Black)
18
SF THRUST WASHER (White)
19
SF NUT
31
20
SF WATER CAP (Use for service only)
30
21
RF PLUG (Use for service only)
32
22
O-RING (On Filter Case)
23
O-RING (On Vent Screw)
24
O-RING (On Hose Connections)
25
RETURN FITTING (RF)
26
RF GASKET (Black)
27
RF THRUST WASHER (White)
28
RF NUT
21
25
26
29
RF ELBOW 90°
30
RF DIVERTER FITTING
31
RF LOCKING RING
24
32
POOL WALL
18
20
16
17
1 POWER FILTER INSTALLATION:
WARNING - EXTREMELY IMPORTANT!
• Risk of electrical shock, connect only to a grounding type receptacle
protected by a ground fault circuit interrupter, (GFCI). Contact a
qualified electrician if you cannot verify that the receptacle is
protected by a GFCI.
• Receptacle must be at least 10 feet away from pool.
• Filter system can be used as many hours as desired.
• Do not use an extension cord to connect unit to electric
supply; provide a properly located outlet.
• Do not bury the cord.
-
NOTE
The Power Filter will be in four sections: a pump; filter assembly; hardware bag; and suction / return hoses.
A. First, remove the Seal Top Retainer (10), Seal Top (9), and Filter Cartridge (15) from the assembled Filter Case.
Lubricate the pump O-ring with petroleum jelly. Hold the filter case (8) securely, and insert motor pump so that
the outlet on the volute housing extends out of the opening in the side of the filter case. Insert the motor pump
until the two ribs on the inlet of the volute housing protrude through the bottom of the filter case. Reach down
inside the filter case and place the Pump Retaining Nut (7) over the top of the volute housing inlet. Twist the Nut
(7) clockwise until it is snug. See Fig. 2.
B. Get the Suction and Return Hoses (12, 13), and remove two Hose
Clamps (14), from the hardware bag. Loosen the hose clamps and
slide them over one end of each hose. Lubricate O-rings (24) on the
Filter Case (8) and Volute Housing liberally with petroleum jelly.
Install one hose on the filter case suction inlet at the top, and one
hose on the filter case return outlet at the base. Tighten both of the
Hose Clamps (14).
C. Locate the Return Fitting assembly parts (21, 25-31). Lubricate the
(black) RF Gasket (26) liberally with petroleum jelly and install it over
the threads on the Return Fitting (25). Insert the Return Fitting (25)
with the RF Gasket (26) through the pool return fitting hole in the
wall from the inside of the pool, see Fig. 3 for correct location. Place
the (white) RF Thrust Washer (27) over the Return Fitting and then
thread the RF Nut (28) onto the fitting until it is hand tight. DO NOT
over tighten the RF Nut or wrinkle the pool wall around the RF Thrust
Washer (27) or the RF Gasket (26). Plug the pool's Return Fitting (25) with the RF Plug (21) from the inside of the
pool. Set the RF Diverter Fitting (30) and RF Locking Ring (31) aside for later installation. Now locate the Pool
Suction Fitting assembly parts (16-20). Lubricate the (black) SF Gasket (17) liberally with petroleum jelly and
install it over the threads on the Suction Fitting (16). Insert the Suction Fitting (16) with SF Gasket (17) through
the pool suction fitting hole in the wall from the inside of the pool. Place the (white) SF Thrust Washer (18) over
the Suction Fitting and then thread the SF Nut (19) onto the fitting until it is hand tight. DO NOT over tighten
the SF Nut or wrinkle the pool wall around the SF Thrust Washer (18) or the SF Gasket (17). Cap the pool's
Suction Fitting (16) with the SF Water Cap (20). Only hand tighten the Water Cap (20). Start filling pool.
D. After the pool is filled, position the Filter Assembly between the two fittings on the side of the pool, about 6
inches out from the base. The suction hose (12), coming from the top of the filter case should be facing the right,
and the return hose (13) coming from the pump, on the lower side of the case, should be facing the left; see Fig.3.
Should you encounter any problems, contact the Customer Service at (888) 919-0070.
Extended operating days and hours during peak season requirements.
3
4
(Reference Page 3, Fig. 1)
Volute
Housing
Volute
Outlet
Housing
Inlet
Motor Pump
FIG. 2
POOL
POOL
RETURN
SUCTION
FITTING
FITTING
FIG. 3
7
8

Advertisement

loading
Need help?

Need help?

Do you have a question about the RP TYPE and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Rp400Rp600Rp800Rp1000Rp2000