IMPORTANT SAFETY INSTRUCTIONS
2
1. POWER FILTER INSTALLATION
4
2. PUMP OPERATION
5
3. PUMP MOTOR PROTECTION
5
4. FILTER CARTRIDGE CLEANING INSTRUCTIONS
5
5. POOL MAINTENANCE
6
6. POOL WATER CARE
6
7. TROUBLE SHOOTING GUIDE
7
8. POWER FILTER DISASSEMBLY AND STORAGE
8
PARTS LIST
9
ASME COMPLIANT SUCTION FITTING INFO
10
Should you encounter a problem with your Polygroup Product, please do not return the product to the
place or purchase. All Warranty claims must be made directly to Polygroup. Prior to contacting Cus-
tomer Service, please first review the Troubleshooting Guide in the Installation Manual, or review the
FAQ at www.polygroup.com. Please review setup instruction videos on www.polygroup.com/video. If
you are still unable to correct the problem, please contact Polygroup customer service at (888) 919-
0070. Have the product type and your purchase receipt ready. Our Customer Service Representative
will assist you in resolving the problem. You may be asked to return all or part of the product for
inspection and/or repair. Do not return any product to Polygroup without a Return Authorization
number.
F700C
F1000C / F1500C / F2000C
1
084-120841 with GFCI - 2015
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions
should always be followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS
WARNING -
To reduce the risk of injury, do not permit children to use this product
unless they are closely supervised at all times.
WARNING -
Risk of Electric Shock. Connect only to a grounding type receptacle. This
product is provided with a ground-fault circuit-interrupter. If replacement of the plug or
cord is needed, use only identical replacement parts.
WARNING -
To reduce the risk of electric shock, replace damaged cord
immediately.
WARNING -
To reduce the risk of electric shock, do not use extension cord to
connect unit to electric supply; provide a properly located outlet.
CAUTION -
To reduce the risk of electric shock the pool must be installed no closer
than 6 feet (1.8 m) from any electrical outlet. Do not place portable appliances closer
than 5 feet (1.5 m) from the pool.
CAUTION -
This pump is for use with storable pools only. Do not use with
permanently-installed pools. A storable pool is constructed so that it is capable of being
readily disassembled for storage and reassembled to its original integrity. A
permanently-installed pool is constructed in or on the ground or in a building such that
it cannot be readily disassembled for storage.
Do not bury cord. Locate cord to minimize abuse from lawn mowers, hedge trimmers, and other equipment.
The unit is provided with a ground-fault circuit-interrupter (GFCI). To test the GFCI, push the test button. The GFCI should
interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is
defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing,
indicating the possibility of an electric shock. Do not use this pump. Disconnect the pump and have the problem
corrected by a qualified service representative before using.
SAVE THESE INSTRUCTIONS
PRELIMINARY STEPS
1. READ ALL INSTRUCTIONS CAREFULLY and get a thorough understanding of what is required to assemble your Type
RP Power Filter.
2. Before you begin to assemble the pool, identify, count, and check all parts needed for assembly.
3. It is recommended that you have some PETROLEUM JELLY on hand for lubricating the gaskets.
POWER FILTER IMPORTANT NOTES:
1. Installer shall follow written instructions provided for operation of the circulation systems.
2. All electrical components shall be installed in accordance with Article 680 of the National Electrical Code (NEC) "Swim-
ming Pools, Fountains and Similar Installations" or its latest approved edition.
3. The Filter Cartridge (15) 3-3/4" will hold as many as 2 of the 1" diameter chlorine tablets and the 8" will hold as many as
6 of the 1" diameter chlorine tablets. Check your chlorine levels to determine the proper number of chlorine tablets to
add. The filter cartridge will automatically dispense chlorine into the pool as the pump runs.
You must have the type of Filter Cartridge (15) with a central core mesh divider (See page 3) to use the chlorine
dispenser. DO NOT use this to dispense powdered chlorine, shock treatment or any other type of chemicals as
damage to the pump, filter cartridge, and pool will occur.
4. The RP Type pump/filter systems are manufactured by Polygroup and ETL control number 4000608 - double insulated
and grounded - 115 V.A.C. - 60 Hz. (ALL Units must have a minimum of 105 V.A.C. to start and run properly.)
2
How to use the GFCI plug:
Press
"RESET"
Button
To Start
Pump
Operation
*Do not connect
to a timer device

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RP800/F700C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Polygroup RP800/F700C

  • Page 1 0070. Have the product type and your purchase receipt ready. Our Customer Service Representative 4. The RP Type pump/filter systems are manufactured by Polygroup and ETL control number 4000608 - double insulated and grounded - 115 V.A.C. - 60 Hz. (ALL Units must have a minimum of 105 V.A.C. to start and run properly.) will assist you in resolving the problem.
  • Page 2 Pump System Wattage Amperage 1 POWER FILTER INSTALLATION (Reference Page 3, Fig. 1) RP800 Filter System with F700C Pump 57 watts 1.1 amps A. First, remove the Seal Top Retainer (10), Seal Top (9), and RP1000 Filter System with F1000C Pump 80 watts 2.2 amps Filter Cartridge (15) from the assembled Filter Case.
  • Page 3: Pump Operation

    SF Water Cap (20), only hand tighten the Water Cap. To vent the filter, slowly unscrew the Vent Screw (11). Press down C. The pool can be cleaned using a garden hose powered vacuum from Polygroup or a pool supply store.
  • Page 4: Troubleshooting Guide

    Pump against defects in material and workmanship for 180 days from the date of purchase. Original Purchaser must retain proof of such purchase in the form of an original store sales receipt and must produce such upon request by Polygroup or its designated agents. Warranty 7 TROUBLE SHOOTING GUIDE claims cannot be processed without a valid proof of purchase.
  • Page 5: Important Safety Instructions

    ASME COMPLIANT SUCTION FITTING INFO PSF-100A AND PSF-100B SUCTION OUTLET FOR ABOVE GROUND POOL IMPORTANT SAFETY INSTRUCTIONS (1) READ AND FOLLOW ALL INSTRUCTIONS (1) PSF-100A and PSF-100B Suction Outlets are certified by IAPMO in accordance with the ASME/ANSI A112.19.8b- 2009 Suction Fitting for use in Swimming Pools, Wading Pools, Spas, and Hot Tubs. (2) This is a submerged suction outlet for use with above ground swimming pool.

This manual is also suitable for:

Rp1000/f1000cRp1000/f1500cRp2000/f2000c

Table of Contents