2-1. Specifications
<Heat Pump Models>
RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E / RAS-4M27GAV-E, RAS-3M26GAV-E
Indoor
Unit model
Outdoor
Cooling capacity
Cooling capacity range
Heating capacity
Heating capacity range
Power supply
Indoor
Electric
characteristics
Outdoor
COP (Cooling/Heating)
Indoor
(Cooling/Heating)
Operating
noise
Outdoor
(Cooling/Heating) Full indoor units operating (dB•A)
Unit model
Dimension
Indoor unit
Net weight
Fan motor output
Air flow rate (Cooling/Heating)
Unit model
Dimension
Net weight
Outdoor unit
Compressor
Fan motor output
Air flow rate
Type
Indoor unit
Outdoor unit
Piping
connection
Maximum length (per unit)
Maximum length (total)
Maximum chargeless length
Maximum height difference
Name of refrigerant
Weight
Power supply
Wiring connection
Interconnection
Indoor
Usable temperature
range
Outdoor
Unit model
Installation plate
Wireless remote controller
Batteries
Remote controller holder
Indoor unit
Zeolite-plus filter
Plasma pure filter
Accessory
Remote controller holder mounting screw
Owner's manual
Mounting screw
Installation manual
Unit model
Outdoor
Installation manual
unit
Specifications
• For performance when each indoor unit is combined with other unit, refer to the separate table.
• The specifications may be subject to change without notice for purpose of improvement.
(kW)
(kW)
(kW)
(kW)
Unit model
Running current
(A)
Power consumption
(W)
Power factor
(%)
Unit model
Operation mode
Running current
(A)
Power consumption
(W)
Power factor
(%)
Starting current
(A)
Unit model
High
(dB•A)
Medium
(dB•A)
Low
(dB•A)
Unit model
Height
(mm)
Width
(mm)
Depth
(mm)
(kg)
(W)
(m³/h)
Height
(mm)
Width
(mm)
Depth
(mm)
(kg)
Motor output
(W)
Type
Model
(W)
(m³/h)
Unit model
Liquid side/Gas side
Unit model
A unit liquid side/Gas side
B unit liquid side/Gas side
C unit liquid side/Gas side
D unit liquid side/Gas side
(m)
(m)
(m)
(m)
(kg)
(Cooling/Heating)
(°C)
(Cooling/Heating)
(°C)
RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E
RAS-4M27GAV-E
8.0
1.4 – 9.2
9.0
0.8 – 11.0
220–240 V, 1 Ph, 50Hz / 220 V, 1 Ph, 60Hz
RAS-B10GKVP-E
RAS-B13GKVP-E
0.15
30
91/87/83
RAS-4M27GAV-E
Cooling
Heating
11.60/11.09/10.63
10.44/9.98/9.57
2500
2250
98
98
11.60/11.09/10.63
3.20/4.00
RAS-B10GKVP-E
RAS-B13GKVP-E
42/43
33/34
27/27
RAS-4M27GAV-E
48/48
RAS-B10GKVP-E
RAS-B13GKVP-E
250
790
215
9
30
550/610
RAS-4M27GAV-E
795
900
320
65
Twin rotary type with DC-inverter variable speed control
DA220A2F-20L
High : 3000, Medium : 2800
Flare connection
RAS-B10GKVP-E
RAS-B13GKVP-E
Ø6.35/ Ø9.52
RAS-4M27GAV-E
Ø6.35/ Ø12.7
Ø6.35/ Ø9.52
Ø6.35/ Ø9.52
Ø6.35/ Ø9.52
25
70
70
15
3 Wires : includes earth
4 Wires : includes earth
21 to 32/0 to 28
10 to 43/–5 to 24
RAS-B10GKVP-E
RAS-B13GKVP-E
1
1
2
1
1
1
2 (Ø3.1 × 16L)
1
6 (Ø4 × 25L)
1
RAS-4M27GAV-E
1
1
– 6 –
RAS-3M26GAV-E
7.5
1.4 – 8.9
9.0
0.8 – 10.8
RAS-B16GKVP-E
0.15
30
91/87/83
91/87/83
RAS-3M26GAV-E
Cooling
10.44/9.98/9.57
11.83/11.31/10.84
2250
98
11.83/11.31/10.84
3.33/3.53
RAS-B16GKVP-E
43/44
45/45
34/35
36/36
27/27
29/29
RAS-3M26GAV-E
48/48
RAS-B16GKVP-E
250
790
215
9
30
560/640
640/660
RAS-3M26GAV-E
795
900
320
64
2000
60
RAS-B16GKVP-E
Ø6.35/ Ø9.52
Ø6.35/ Ø12.7
RAS-3M26GAV-E
Ø6.35/ Ø12.7
Ø6.35/ Ø9.52
Ø6.35/ Ø9.52
25
50
50
15
R410A
2.4
RAS-B16GKVP-E
1
1
2
1
1
1
2 (Ø3.1 × 16L)
2 (Ø3.1 × 16L)
1
6 (Ø4 × 25L)
6 (Ø4 × 25L)
1
RAS-3M26GAV-E
1
1
0.15
30
Heating
2550
98
250
790
215
9
30
1
1
2
1
1
1
1
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents