Download Print this page

Audiovox Prestige APS-920 Installation Manual page 13

This remote start/alarm system is designed to be used with prestige automatic transmission-fuel injection vehicles only
Hide thumbs Also See for Prestige APS-920:

Advertisement

3 Wire Positive Switched Door Lock Circuits:
In this application, the Red wire of the 2 pin harness provides a Positive pulse during the
arming sequence, or pulsed 12 Volt lock output. Connect the Red wire to the low current 12 volt
signal wire from the factory door lock switch to the factory door lock relay.
The Green wire of the 2 pin harness provides a Positive pulse during the disarming sequence,
or pulsed 12 Volt unlock output. Connect the Green wire to the low current 12 volt signal wire
from the factory door unlock switch to the factory door unlock relay.
Positive Type Door Lock Circuits
13
128-7853A
13 of 16

Advertisement