Download Print this page

American Standard SYMPHONY 4501 Installation Instructions

Pressure balancing bath and shower trim kits

Advertisement

Quick Links

SYMPHONY
PRESSURE BALANCING BATH
AND SHOWER TRIM KITS
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
ROUGHING-IN DIMENSIONS
To assure proper positioning in relation
to wall, note roughing-in dimensions.
3-5/8" REF.
74" FOR HEAD
CLEARANCE
18" OPTIONAL
1
ROUGHING-IN
When soldering, remove PLASTER GUARD, CARTRIDGES and CHECK STOPS (IF PRESENT). When finished soldering,
NOTE
flush valve body, replace cartridges, check stops (if present) and plaster guard to continue installation. Use thread
sealant or Teflon tape on threaded connections.
See Roughing-in diagram before starting.
Connections are:
1/2" female NPT for threaded inlets
Connect RISER PIPE (1) to MANIFOLD (2)
top outlet marked "SHR".
Connect TUB FILLER PIPE (3) at bottom
outlet marked "TUB".
For proper positioning the finished wall
must be within side wall of PLASTER
GUARD (4).
1-5/8" TO 3-1/4"
FINISHED WALL
1/2" NPT
5-1/2" REF.
"SEE ILLUSTRATION "
3-5/8"
1/2" NPT''
5-1/8" REF.
TOP OF TUB RIM
BOTTOM OF TUB
CAUTION
Turn off water at main supply.
If the valve is installed on a fiberglass
or other thin wall application, the
PLASTER GUARD (4) can be used as a support.
Cut a 4" dia. hole in the shower stall.
Drill two additional 1" holes to allow access
to the stops.
Remove PLASTER GUARD (4), rotate 90˚
so that indicated screw holes fit MANIFOLD (2).
Push CAP on valve, place ESCUTCHEON on and
attach with screws.
Connect hot and cold water supplies.
Cap off shower pipe (5) and tub filler pipe (6).
For support, use pipe BRACES (7) secured to wooden braces.
With valve turned off, turn on water supplies. Check for leaks.
Installation
Instructions
4 5 0 1
4 5 0 1 S
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 80''
3-3/8"
6-3/4"
TUB PORT 1/2" NPT
4"
Certified to comply with ANSI A112.18.1
M 9 6 8 8 0 5 R E V. 1 . 4
INLETS 3-3/8"
SHR. 1/2" NPT
INLETS 1/2" NPT
'
THREADED INLETS
1
2
HOT
3
5
7
COLD
4
6

Advertisement

loading

Summary of Contents for American Standard SYMPHONY 4501

  • Page 1 SYMPHONY PRESSURE BALANCING BATH AND SHOWER TRIM KITS Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. ROUGHING-IN DIMENSIONS To assure proper positioning in relation to wall, note roughing-in dimensions.
  • Page 2 INSTALL TRIM When finished tiling the wall, remove PLASTER GUARD (3). Push on CAP (1). Mount ESCUTCHEON (2) and with SCREWS (7). Install HANDLE (8) by pushing it onto CARTRIDGE STEM (9) and tightening SET SCREW (10) from below with 2.5mm Hex Wrench supplied.

This manual is also suitable for: