Download Print this page
American Standard SERIN 2064.4 Installation Instructions Manual
American Standard SERIN 2064.4 Installation Instructions Manual

American Standard SERIN 2064.4 Installation Instructions Manual

Bidet faucet and transfer valve with speed connect drain

Advertisement

Quick Links

SERIN
Bidet Faucet and Transfer Valve with
Speed Connect™ Drain
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
Speed Connect Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Roughing-in
TRANSFER VALVE
Dimensions
(FOR FLUSHING
RIM OR SPRAY)
BIDET OUTLINE
IS SYMBOLIC
7/8 DIA.
DOUCHE
ADJ. 1-1/4
SPRAY
TO 2-1/4
1-3/8
3-7/8
DIA.
1
BIDET FAUCET INSTALLATION
Place RUBBER RING (10) into ESCUTCHEON (4).
Install LOCKNUT (1) and RUBBER WASHER (2) onto VALVE BODIES (3, 3a). From
under side of mounting surface, install VALVE BODY (3, 3a) through valve mounting
holes. Threads of VALVE BODY (3, 3a) should extent at least 5/16 of a inch above
mounting surface top. Fig. A. Thread ESCUTCHEON (4) onto VALVE BODIES
(3, 3a) until snug against internal stop. If necessary, adjust LOCKNUT (1).
Tighten LOCKNUTS (1) with WRENCH (5) (supplied)
to secure VALVE BODIES (3, 3a).
Remove ESCUTCHEON (6), WASHER (7) and
UPPER GASKET (8) from TRANSFER VALVE (9).
Insert TRANSFER VALVE (9) into the center forward
hole of BIDET.
Replace UPPER GASKET (8) and WASHER (7) and
ESCUTCHEON (6) until it locks against internal stop.
Position the side threaded outlet rearward and
secure MOUNTING NUT (11).
2
SPRAY INSTALLATION
Assemble SPRAY BODY (1) to BIDET. Using putty, seal underside
of SPRAY BODY FLANGE (2) and secure with NUT (3).
Thread SPRAY HOSE (4) with SEAL WASHER (5) to SPRAY BODY (1).
Connect other end of HOSE (4) with SEAL WASHER (6) to side outlet
NIPPLE (7) of the TRANSFER VALVE (8).
Thread SPRAY CAP (9) onto SPRAY BODY (1).
FINISHED
WALL
1-3/16
DIA.
2-1/8
DIA.
1-1/4
MAX.
FINISHED
FLOOR
5-1/2
1-1/4 O.D. TAILPIECE
CAUTION
Installation
Instructions
2064.400
8 TO 12
2-1/4
(C)
(H)
DIA.
4-1/4
FOR GROUND JOINT
CONNECTION OR 1/2 "
O.D. SLIP (INLETS)
REAR VIEW WITH
WALL REMOVED
Turn off hot and cold water
supplies before beginning.
4
Fig. A.
10
5/16''
MOUNTING
MIN.
SURFACE
3, 3a
6
Certified to comply with ANSI A112.18.1
Recommended tools
Screwdriver
Phillips Screwdriver
Adjustable Wrench
4
10
3
2
HOT
1
2
1
5
2
8
PUTTY
7
3
4
M968924 Rev.1.3
Plumbers' Putty or
Caulking
Channel Locks
Tubing Cutter
6
7
BIDET
LEDGE
8
3a
COLD
9
11
9
1
5
4

Advertisement

loading

Summary of Contents for American Standard SERIN 2064.4

  • Page 1 • Never needs adjustment • Guaranteed to seal properly the first time, every time. *Your new American Standard faucet is designed to work only with the Speed Connect drain. To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
  • Page 2 POP-UP DRAIN Remove CLEAR PLASTIC COVER (1). Remove CARDBOARD SPACER (2) from under DRAIN POP-UP (3). Tighten TAILPIECE (4) on DRAIN BODY before Fig. B. installing DRAIN BODY. REMOVE FLANGE Thread FLANGE (1) counter-clockwise and remove FLANGE (1) and FOAM GASKET (2) from drain Fig.
  • Page 3: Water Supply Connection

    ATTACH CABLE CONNECTOR POP-UP KNOB (1) must be fully down. Fig. A. Thread CABLE CONNECTOR (1) clockwise onto DRAIN BODY CONNECTION (2) and hand tighten. Fig. B. Your new POP-UP DRAIN installation is now complete. Fig. C. Note: Tailpeice on pop-up drain is 1-1/4”...
  • Page 4: Install Handles

    INSTALL HANDLES Push ADAPTER (1) on VALVE STEM (2), so that the hole of the ADAPTER (1) without a spline is facing up. See figure "A". Tighten STEM SCREW (3) to secure ADAPTER (1). Find correct position of LEVER HANDLE ASSEMBLY (4) by adjusting male teeth on ADAPTER (1) to female teeth in HANDLE (4).
  • Page 5: Troubleshooting Guide

    Speed Connect™ Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the “down” position: • Follow CABLE ADJUSTMENT PROCEDURE. If Stopper does not raise up fully or sink drains too slowly: • Follow CABLE ADJUSTMENT PROCEDURE. If you need to remove the Stopper: •...
  • Page 6 To install the stopper in “Unlocked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear. Rotate Stopper slightly if necessary so that the Stopper slides all the way down.
  • Page 7: Model Numbers

    M962508-YYY0A M950245-YYY0A HANDLE ASSEMBLY M962414-YYY0A ESCUTCHEON KIT M962481-YYY0A LIFT ROD GUIDE 918555-0070A HANDLE SCREW 918049-0070A ADAPTER 994053-0070A CARTRIDGE (INCLUDING SEALS) M961634-0070A VALVE MTG. KIT 024220-0070A COUPLING NUT Replace the "YYY" with appropriate finish code CHROME SATIN NICKEL M952426-YYY0A DRAIN ASSEMBLY POP-UP ROD 033772-0070A TEE AND HOSE KIT...