Page 1
APPAREILS DE CHAUFFAGE INDIVIDUELS A AIR FORCE MANUEL D’UTILISATION TRAGBARE HOCHDRUCK-HEISSLUFTTURBINEN BEDIENUNGSANLEITUNG RISCALDATORI MOBILI AD ARIA FORZATA MANUALE OPERATIVO CALENTADORES MÓVILES DE AIRE FORZADO MANUAL DE INSTRUCCIONES MODELS - MODELES - MODELLE - MODELLI - MODELOS: BLP 100 E - BLP 100 M...
Page 2
CONTROL BOARD TABLEAU DE COMMANDE KONTROLLTAFEL QUADRO COMANDI TABLEO DE MANDOS CONTROL BOARD - TABLEAU DE COMMANDE - KONTROLLTAFEL QUADRO COMANDI - TABLEO DE MANDOS Reset button with control lamp Bouton de réarmement avec lampe témoin “E” Reset Knopf mit Kontrollampe Pulsante riarmo con spia Pulsador restablecimiento con testigo Room thermostat socket...
GENERAL INFORMATIONS SAFETY RECOMMENDATIONS INSTALLATION INSTRUCTIONS OPERATING INSTRUCTIONS STOPPING THE HEATER VENTILATION SAFETY DEVICES GENERAL INFORMATIONS • Set regulator at the lowest pressure and press stop gas valve once. • On “E” models only, set switch (6) on position ; the fan rotates To obtain full benefit from your air heater and avoid damage, please and after few seconds the combustion begins.
MOVING THE HEATER MAINTENANCE WARNING: During proper heater work, the control lamp of the reset button can blink for short periods for regular intersals: this doesn’t represent a malfunction warning. While in case of heater “block”, instead, the warning lamp will remain on and it will periodi- cally blink.
Page 5
OBSERVED FAULT, POSSIBLE CAUSES AND REMEDIES OBSERVED FAULT, POSSIBLE CAUSES AND REMEDIES N° CAUSE OBSERVED FAULTS Model “E” Model “M” Air heater does not start 1-2-3-4-5-6 1-2-5 Air heater stops burning and lamp (1) lights up 6-7-8-9-10-11-21-22 Fan turns but the gas supply is blocked or fails to ignite 8-11-12-13-14-15 The flame extinguishes completely after the press-button (7) is released 14-16-17...
WIRING DIAGRAM SCHEMA ELECTRIQUE ELEKTRISCHES SCHEMA SCHEMA ELETTRICO ESQUEMA ELÉCTRICO WIRING DIAGRAM - SCHEMA ELECTRIQUE - ELEKTRISCHES SCHEMA SCHEMA ELETTRICO - ESQUEMA ELÉCTRICO MOD. “M” FAN MOTOR FUSE 4A PIEZIGNITER MOTEUR DU VENTILATEUR FUSIBLE 4A PIEZOELECTRIQUE VENTILATOR MOTOR SICHERUNG 4A PIEZOZÜNDER MOTORE VENTILATORE FUSIBILE 4A...
Page 8
ELECTRODES ADJUSTMENT AND THERMOCOUPLE REGLAGE DES ELECTRODES ET THERMOCOUPLE EINSTELLUNG DER ELEKTRODEN UND THERMOELEMENT REGOLAZIONE ELETTRODO E TERMOCOPPIA REGULACIÓN ELECTRODO Y TERMOPAR ELECTRODES ADJUSTMENT AND THERMOCOUPE REGLAGE DES ELECTRODES ET THERMOCOUPE EINSTELLUNG DER ELEKTRODEN UND THERMOELEMENT REGOLAZIONE ELETTRODO E TERMOCOPPIA REGULACIÓN ELECTRODO Y TERMOPAR 30 mm...
Need help?
Do you have a question about the BLP 100 E and is the answer not in the manual?
Questions and answers