Connecting Power; Ac Power; Dc Power - Nortel 700117 Hardware Installation Manual

10/100/1000 mbps web switches
Table of Contents

Advertisement

Connecting Power

The following instructions are for AC powered and DC powered Alteon switches.

AC Power

1.
Connect the power cord to the Web switch. Verify that the power switch is in the off
position.
2.
Plug the switch cord into a properly fused AC outlet.
3.
Power On (|) the switch.
C
AUTION
!
of fire, replace only with the same type and rating fuse. French: Attention–Utiliser un fusible
de rechange de meme type.

DC Power

The wire terminal block on the back of the chassis is for connecting the lead wires for standard
DC power.
Follow the instructions below to connect the switch to a -48 to -60 VDC SELV source only, in
compliance with National Electrical Code (NEC) articles 110-26 and 110-27.
1.
Be sure that DC power is turned off at the source.
2.
Connect your DC earth-ground lead to the switch
The switch must be connected to a protective earthing terminal in accordance to National Elec-
trical Code (NEC) article 250-160.
Use copper conductor wire of #12 to #22 AWG. Strip 1 cm of the insulation from one end of
the ground wire. Loosen the cap of the module's earth-ground terminal (marked
insert the bare end of the wire into the terminal's wire slot.
Make sure that the bare wire makes contact with the metal terminal post. Finally, tighten the
terminal cap to secure the wire into place.
3.
Connect the other end of the DC earth-ground lead to the earth-ground terminal on your
DC power source.
4.
Connect each remaining DC power lead to the appropriate wire terminal on the switch.
Be sure to use copper conductor wire of #12 to #22 AWG when connecting to the terminals.
212779-A, December 2001
—The switch uses a 3A/250V fast-acting fuse. For continued protection against risk