Ebac CD425 Owner's Manual
Hide thumbs Also See for CD425:

Advertisement

EBAC MODEL CD425
DEHUMIDIFIER
OWNER'S MANUAL
Ebac Commercial Ltd
St Helens Trading Estate
Bishop Auckland
Co. Durham
DL14 9AD
Telephone: (01388) 664400 Fax: (01388) 662590
Website: www.ebacuk.com
CD425 OWNERS MANUAL
Drawing No. :- TPC127a
Issue
:- 1
Date
:- 26/06/03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CD425 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ebac CD425

  • Page 1 Drawing No. :- TPC127a Issue :- 1 Date :- 26/06/03 EBAC MODEL CD425 DEHUMIDIFIER OWNER’S MANUAL Ebac Commercial Ltd St Helens Trading Estate Bishop Auckland Co. Durham DL14 9AD Telephone: (01388) 664400 Fax: (01388) 662590 Website: www.ebacuk.com CD425 OWNERS MANUAL...
  • Page 2 The CD425 is a self contained low temperature dehumidifier. All electrical contactors, overloads, etc, are housed in an electrical box built inside the unit. The unit is equipped with a defrost valve which energises every 42 minutes to clear any ice formation on the evaporator coils.
  • Page 3: Specifications

    :- 1 Date :- 26/06/03 SPECIFICATIONS CD425 ODEL 1190mm EIGHT 1100mm IDTH 460mm EPTH 160 Kg EIGHT 3000 M IRFLOW 380-415V, 3 ph, 50Hz OWER UPPLY 6.0 Kw (max) OWER Vinyl coated steel INISH R407c (2.5Kg) EFRIGERANT CD425 OWNERS MANUAL...
  • Page 4: Installation

    Connect the outlet from the drain tray (located behind the front grille and under the evaporator coils) to a permanent drain. Please ensure that the drainage does not rise above the level of the CD425’s drain tray. Failure to observe this requirement will result in internal flooding of the dehumidifier unit.
  • Page 5: Operation

    During the defrost cycle the defrost solenoid valve is energized and a warming of the evaporator coil can be felt. If after carrying out the above checks the unit does not appear to function correctly, refer to your supplier. CD425 OWNERS MANUAL...
  • Page 6: Routine Maintenance

    Check the machine again after a further hour of operation to determine that the valve is working correctly. F ANY OF THE PRECEDING PROBLEMS OCCUR CONTACT THE ERVICE ENTER PRIOR TO CONTINUED OPERATION OF THE UNIT TO PREVENT PERMANENT DAMAGE CD425 OWNERS MANUAL...
  • Page 7 An open circuit indicates that the compressor should be replaced. c. Check that the compressor is not grounded by establishing that a circuit does not exist between the compressor terminals and the shell of the compressor. CD425 OWNERS MANUAL...
  • Page 8: Troubleshooting

    1. Clear the obstruction Water flooding inside 2. Drain pipe too high 2. Lower section of pipe machine Ebac Commercial Ltd St Helens Trading Estate Bishop Auckland Co. Durham DL14 9AD Telephone: (01388) 664400 Fax: (01388) 662590 Website: www.ebacuk.com CD425 OWNERS MANUAL...
  • Page 9: Spare Parts List

    Fan Motor Assembly 3030130 Defrost Valve 3020815 Electronic Timer 1601200 Aux Contactor 3030354 Aux Contactor 3030350 Terminal Block 3031460 Solenoid Coil 3030449 Contactor 3030362 Power Cord 3035148 27ft Drain Tray 2131107 Drain tube P-clip 3035697 Drain Tubing 3014315 25ft CD425 OWNERS MANUAL...