Error Messages
C:DRIVE ERROR
C:DRIVE FAILURE
CH-2 TIME ERROR
CMOS CHECKSUM ERROR
CMOS SETTINGS WRONG/CMOS DISPLAYTIME WRONG
CMOS CHECKSUM BAD
CMOS SYSTEM OPTIONS NOT SET
CMOS TIME AND DATE NOT SET
DISK BOOT FAILURE, INSERT SYSTEM DISK AND PRESS ENTER Insert system disk in
NON SYSTEM DISK OR DISK ERROR
DISK DRIVES OR TYPES MISMATCH ERROR - RUN SETUP CMOS Check drive type in Setup. Change jumper setting if necessary.
DISPLAY SWITCH IS SET INCORRECTLY
DISPLAY TYPE HAS CHANGED SINCE LAST BOOT
ERROR ENCOUNTERED INITIALIZING HARD DISK DRIVE/ ERROR
INITIALIZING HARD DISK CONTROLLER
HDD CONTROLLER FAILURE
FLOPPY DISK CNTRLR ERROR/ NO CNTRLR ERROR/ NO CNTRLR
PRESENT
FDD CONTROLLER FAILURE
KEYBOARD ERROR/ NO KEYBOARD PRESENT
KB/ INTERFACE ERROR
PS/2 MOUSE ERROR
MEMORY SIZE HAS CHANGED SINCE LAST BOOT
MEMORY VERIFY AT...
MEMORY PARITY ERROR AT...
I/O CARD PARITY ERROR AT...
PRESS A KEY TO REBOOT
PRESS F1 TO DISABLE NMI, F2 TO REBOOT
RAM- CHECKING FOR SEGMENT...
SYSTEM HALTED, (CTRL-ALT-DEL) TO REBOOT
The computer beeps...
1,2 or 3 times
5 times
6 times
9 times
4,7,8,10 times
50%
Paper not bleached with chlorine
Recommended Action
Check hard disk type in Setup.
Replace hard disk.
Replace system board.
Run Setup, replace battery if error persists.
Reboot, then set time and date in Setup
and press
. When booting from hard disk, check hard disk controller installation and
A:/
Enter
cables.
Check video setting in Setup.
Check video setting in Setup.
Check hard disk controller installation, cables and jumper configuration. Check disk type in Setup.
Check FDD controller installation. If no FDD is installed, run Setup and disable floppy drive.
Check keyboard is correctly connected. Make sure no keys are pressed during boot.
Check keyboard is correctly connected.
Check mouse is correctly connected.
Check memory size in Setup.
Use specified location to locate bad memory module.
Use specified location to locate expansion card failure.
An error has occurred, press any key to reboot.
BIOS detects NMI (Non-Maskable Interrupt). Press F2 to reboot or F1 to disable NMI.
Change bad RAM module.
Boot attempt aborted. Press Ctrl + Alt+ Del to reboot.
You should...
Reset memory DIMMs, replace it if necessary.
Reset the processor, replace it if necessary.
Change the keyboard or replace the fuse if applicable.
Replace system board.
Replace the system board or video controller.