Patio gas infrared heater with 2-stage modulation (21 pages)
Summary of Contents for Schwank 2300 Series
Page 1
>Shut off gas to the appliance INSTALLATION CODE” in Canada, and the >Extinguish any open flames ANSI Z223.1 (latest edition) in the U.S.A. >Don’t touch electrical switches >Call your Gas supplier immediately MEMBER OF 2300 / IO 210 Manual IM091231 RD: DEC 2009 R.L. 11B...
Page 2
This publication, or parts thereof, may not be reproduced in any form, without prior written consent from the manufacturer Unauthorized use or distribution of this publication is strictly prohibited. Schwank Group PO Box 988, 2 Schwank Way Waynesboro, Georgia, USA 30830 5285 Bradco Boulevard...
Page 4
Clothing or other flammable materials should not be hung from, or placed near to the heater. Warning Keep this appliance area free from combustible materials, gasoline and other flammable vapours and liquids. 2300 / IO 210 Manual IM091231 RD: DEC 2009 R.L. 11B...
2. INSTALLATION REQUIREMENTS 2.1 MOUNTING CLEARANCES Series 2300 / IO 210 Heaters must be mounted with minimum clearances as shown in Section 8.4. It should also be located with respect to building construction and equipment so as to provide sufficient clearance and accessibility for servicing and cleaning of burners and ignition control.
Observe the minimum clearances as outlined in Sections 8.4 and suggested mounting dis- tances in section 8.5 WARNING: When using Wall Mounting Bracket JP-2300-MB, or Arm Mounting Bracket JP- 2300-MA, ensure the anchoring to the structure is of sufficient strength, quality and workmanship, to support the weight of the heater and any other loads such as snow.
- insert a paper masking above the lens screen being coated. Remove the paper masking immediately after re-finish and prior to operation of the heater. 2300 / IO 210 Manual Page 3 IM091231 RD: DEC 2009 R.L.
If heater backfires during operation, it must be turned off immediately. HEATER SERVICING INSTRUCTIONS: WHEN USING WALL MOUNT BRACKET JP-2300-MB: 1. Slacken the upper bolt to allow the rotation of the mounting bracket and the heater. 2. Remove the lower bolt securing the bracket and rotate the bracket up to the service position.
JP-2300-PC POST BRACKET WARNING: When using Wall Mounting Bracket JP-2300-MB, or Arm Mounting Bracket JP- 2300-MA, ensure the anchoring to the structure is of sufficient strength, quality and workmanship, to support the weight of the heater and any other loads such as snow.
MOUNTING OPTIONS FOR THE 2300 SERIES HIGH INTENSITY HEATERS Diagram 2: MOUNTING KIT OPTIONS WALL MOUNTING BRACKET POST MOUNTING BRACKET CHAIN HANGING SUPPORT ARM MOUNTING BRACKET (SUPPLIED WITH HEATER) (WITH GAS HOSE AND WIRING) Diagram 3: MOUNTING OPTIONS WALL MOUNTING...
Page 13
NOTE: The heater should be installed with enough slack on the wiring and a flexible gas con- nector to allow the rotation of the heater up to the service position. (See service installation on the next page). 2300 / IO 210 Manual Page 9 IM091231 RD: DEC 2009 R.L.
Note: These mounting angles and distances are suggested, and are subject to site and design condi- tions. If in doubt, please contact your Schwank distributor. Ensure mounting height in any location is sufficient to prevent patio patrons from coming in con-...
24 volts for a period of 5 seconds. If the thermostat is still calling for heat af- ter one hour the control will automatically reset and attempt to ignite the burner again. 2300 / IO 210 Manual Page 13...
Page 18
3. Exceeding the temperature limits can cause nuisance lockouts and premature elec- trode failure. The control must be secured in an area that will experience a minimum of vibration and remain below the maximum operating temperature of 160°F. 2300 / IO 210 Manual Page 14 IM091231 RD: DEC 2009...
3 A spark length of 1/8 in. (3mm) or more indicates satisfactory voltage output. If no arc can be established, or the maximum spark is less than 1/8 in. (3mm), and power to the ignition control input terminals was proved, replace the ignition control. 2300 / IO 210 Manual Page 15 IM091231 RD: DEC 2009...
12. WIRING DIAGRAM FOR 2300 / IO 210 SERIES with Fenwal 35-60 DSI Control If installing remote control; JP-1234-RK, refer to wiring diagram in the remote con- trol manual Fenwal Control Terminal Designation Error Mode LED Indication Internal Control Failure...
*CHECK CERAMIC INSULATOR FOR CRACKS * VALVE IS OPEN AND THAT *CHECK SPARK GAP, 1/8”-3/16” . THERE IS GAS SUPPLY TO *CHECK IGNITION CABLE, AND GROUND THE VALVE. WIRE, 2300 / IO 210 Manual Page 17 IM091231 RD: DEC 2009 R.L. 11B...
Page 22
TROUBLE SHOOTING ENDS IF VALVE DOES NOT CLOSE REPLACE GAS VALVE.. NOTE: IF CONTROL GOES INTO LOCKOUT, THE SYSTEM CAN BE RESET BY INTERRUPTING THE POWER SOURCE: 2300 / IO 210 Manual Page 18 IM091231 RD: DEC 2009 R.L. 11B...
MUST PROVIDE FOLLOWING INFORMATION FROM COMMISSIONING REPORT (NEXT PAGE) HIS COMPLETED COMMISSIONING REPORT ON NEXT PAGE FAX COMPLETED FORM TO TECHNICAL SERVICES: CANADA - 905-712-8336 USA - 706-554-9390 2300 / IO 210 Manual Page 19 IM091231 RD: DEC 2009 R.L. 11B...
Page 24
WHAT IS THE GAUGE OF THE LOW VOLTAGE WIRING: GAUGE DOES THE HEATER HAVE GOOD ELECTRICAL GROUNDING: * FAX COMPLETED FORM TO TECHNICAL SERVICES: CANADA - 905-712-8336 USA - 706-554-9390 2300 / IO 210 Manual Page 20 IM091231 RD: DEC 2009...
15. Replacement Parts List Only the following illustrated parts are available. For any other parts please contact the manufacturer. 2300 / IO 210 Manual Page 21 IM091231 RD: DEC 2009 R.L. 11B...
LIMITED WARRANTY CERTIFICATE GAS-FIRED INFRA-RED PATIO HEATERS : 2300 / IO 210 SERIES The Manufacturer warrants that this product is free from defects in material or workmanship under normal use and service subject to the terms of this document. ONE YEAR WARRANTY Subject to the conditions and limitations stated herein, during the term of this limited warranty, we will supply any component part (at our option a new or repaired component part) of the heater, as defined below, excluding any labor, which the Manufacturer’s ex-...