Remote Input Port

e
Wiring for remote control
Options for remote control include the Extron VC 50, VCM 100 AAP, VCM 100 MAAP,
VCM 200 series, and MLA VC10 Plus. For information about part numbers, see
www.extron.com. Third party 10k potentiometer volume controllers can also be
connected to this port.
Figure 4 and the instructions below, show the wiring for the VCM 100 MAAP. Wiring other
remote control connectors is similar.
Volume Pot
10K Ohms
Figure 4.
NOTE: All nominal levels are at ± 10%.
Remote input port — This 3-pin, captive screw
port allows a wall-mounted audio controller to
control volume and mute levels remotely (see
Remote Control Options
MediaLink controller).
NOTE: The remote control port may be labeled
in one of two ways (see the diagram to the
right). The wiring and function are the same
whichever way the product is labeled.
REMOTE
10V
V
C
10 V (Pin 1)
2K
Vol/Mute
(Pin 2)
Mute
Switch
GND (Pin 3)
Remote Control Wiring
Pin 1 is 10 VDC reference voltage.
Pin 2 (Vol/Mute) can be used as a variable voltage input between 0 and 10 VDC, with
0 V giving full attenuation and 10 V giving maximum volume. It can also be used for
remote control muting. Sound is muted while the mute pin is shorted to ground.
Pin 3 is ground.
MPA 401-70V and MPA 401-100V • Rear Panel and Cabling
on page 12 if using a
50mA
G
REMOTE
10V
50mA
10V
50mA
VOL/MUTE
REMOTE
V
C
G
7