Power Input

a
Power receptacle — A 36 W desktop power supply is provided.
ATTENTION:
When the PS 1230 power supply is connected to the MPA 401, it
must not be shared with any other devices.
MPA 401 series
Amplifier
AC Power Cord
POWER
Power Receptacle
12V
1.5 A MAX
DC Power Cord
Captive Screw Connector
Figure 3.
Connecting the PS 1230 Power Supply to an MPA 401 Amplifier
Connect one end of the DC power cord to one of the two pole, 3.5 mm captive screw
outlets on the power supply. Connect the other end into the power receptacle on the
rear panel of the amplifier, as shown in figure 3 above. The power cord connectors are
correctly wired when shipped.
ATTENTION:
Always use a power supply supplied by or specified by Extron. Use of an
unauthorized power supply voids all regulatory compliance certification and
may cause damage to the supply and the end product.
Suitable for use in environmental air space in accordance with
Section 300.22.C of the National Electrical Code, and Sections 2-128,
12-010(3) and 12-100 of the Canadian Electrical Code, Part 1, C22.1.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air
handling spaces or in wall cavities. The power supply is to be located within
the same vicinity as the Extron AV processing equipment in an ordinary
location, Pollution Degree 2, secured to the equipment rack within the
dedicated closet, podium, or desk.
The installation must always be in accordance with the applicable provisions
of National Electrical Code ANSI/NFPA 70 and the Canadian Electrical Code.
The power supply shall not be permanently fixed to building structure or
similar structure.
Although the amplifier is plenum rated, the power supply provided with it
is not. The power supply must not be placed in the plenum space. Cables
to and from the amplifier must also be plenum rated. The DC power cord
provided with the unit is not plenum rated.
The length of the exposed wires in the stripping process is critical. The ideal
length is 3/16 inches (5 mm). Any longer and the exposed wires may touch,
causing a short circuit between them. Any shorter and the wires can be
easily pulled out even if tightly fastened by the captive screws.
NOTE: Do not tin the wires. Tinned wire does not hold its shape and can become
loose over time.
MPA 401-70V and MPA 401-100V • Rear Panel and Cabling
PS 1230 Power Supply
DC Power
Outputs
DO NOT USE
Captive Screw
Connector
Tie
Wrap
Power Supply
Output Cord
MPA 401 series
Amplifier
Ridges
POWER
Smooth
A
A
12V
1.5 A MAX
Power Supply
Output Cord
3/16"
SECTION A–A
(5 mm) Max.