7.
Unscrew the sediment cup.
8.
Clean the sediment cup, O-ring, and filter in non-flammable or high
flash point solvent.
9.
Reinstall the filter, O-ring, and sediment cup.
10.
Turn the fuel valve ON and check for leaks.
11.
Reinstall the air cleaner base, and connect the breather hose to the
air cleaner base.
12.
Reinstall the paper air filter and air cleaner cover.
13.
Close and latch the left side maintenance cover.
SERVICING YOUR GENERATOR
Gasoline is highly flammable and
explosive.
You can be burned or seriously
injured when handling fuel.
Stop the engine and keep heat,
sparks, and flame away.
Handle fuel only outdoors.
Wipe up spills immediately.
SEDIMENT CUP
FILTER
O-RING
SEDIMENT CUP
55