RIGHT OVEN

Oven burner replacement of
injector
– Lift and remove the lower panel
inside the oven.
– Remove the 2 screws securing the
burner (fig. 3.13).
– Withdraw the burner as shown in
figure 3.14 and rest it inside the
oven. Take care not to damage the
wire to the ignition electrode and
the safety valve probe.
– Using a 7 mm box spanner, unscrew
the injector (indicated by the arrow
in fig. 3.14) and replace it by the
proper one according to the kind of
gas.
Then replace the burner repeating
the above steps in reverse order.
Fig. 3.13
Fig. 3.14
22
Regulation of air supply to
oven burner
Using a screwdriver, slacken the
screw securing the air flow regulation
collar (fig. 3.15) and rotate the collar
clockwise or anti-clockwise to
increase or reduce the air aperture in
accordance with gas type and the
indications in the " TABLE FOR THE
CHOICE OF THE INJECTORS ".
Light the burner and check the flame.