Download Print this page

HP 8753ES Specifications page 12

Network analyzers 30 khz to 3 or 6 ghz
Hide thumbs Also See for 8753ES:

Advertisement

HP 8753ES Option 011 specifications
Test port output characteristics
Frequency characteristics
300 kHz to 3 GHz
Range
Option 006
30 kHz to 6 GHz
1 Hz
Resolution
typically ±7.5 ppm 0˚ to 55 ˚C
Stability
typically ±3 ppm/year
typically ±0.05 ppm 0˚ to 55 ˚C
Option 1D5
typically ±0.5 ppm/year
±10 ppm at 25 ˚C ± 5 ˚C
Accuracy
-5 to +20 dBm
Power range
Option 006
-5 to +18 dBm
0.01 dB
Resolution
1,2
±1.0 dB
Level accuracy
1,2,5
±0.25 dB, -5 to +15 dBm
Level linearity
±0.5 dB, +15 to +20 dBm
50
Impedance
2
300 kHz to 3 GHz
>16 dB RL (<1.38 SWR)
300 kHz to 6 GHz >14 dB RL (<1.50 SWR)
Spectral purity
3
<-40 dBc at +10 dBm
2nd harmonic
<-50 dBc at 0 dBm
Option 002
<-25 dBc at max power
4
<-40 dBc at +10 dBm
3rd harmonic
<-50 dBc at 0 dBm
Option 002
<-25 dBc at max power
6
Nonharmonic spurious
<-30 dBc at max power
Mixer related
<-55 dBc at -10 dBm
1. +10 dBm output power for the HP 8753ES Option 011.
2. Typical below 300 kHz.
3. 16 MHz to 3 GHz.
4. 16 MHz to 2 GHz.
5. For HP 8753ES Option 011 and Option 006, linearity is specified for the ranges of -5 to +13 dBm
and +13 to +18 dBm.
6. Typical performance.
nominal
6
6
6
6
Test port input characteristics Option 011
300 kHz to 3 GHz
Frequency range
Option 006
30 kHz to 6 GHz
2
Average noise level
50 kHz to 3 GHz <-90 dBm (3 kHz BW)
50 kHz to 3 GHz <-110 dBm (10 Hz BW)
50 kHz to 3 GHz <-120 dBm (10 Hz BW) typical
3 to 6 GHz
<-85 dBm (3 kHz BW)
3 to 6 GHz
<-105 dBm (10 Hz BW)
3 to 6 GHz
<-115 dBm (10 Hz BW) typical
Maximum input level
20 dBm or 25 VDC
Damage level
50 ohms nominal
Impedance:
300 kHz to 2 MHz
2 MHz to 1.3 GHz
1.3 GHz to 3 GHz
Option 006
3 GHz to 6 GHz
Frequency response
300 kHz to 3 GHz
3 GHz to 6 GHz
Harmonics (Option 002)
3
<-15 dBc at 0 dBm
2nd harmonic
<-30 dBc at -10 dBm
<-45 dBc at -30 dBm
4
<-30 dBc at 0 dBm
3rd harmonic
<-50 dBc at -10 dBm
<-50 dBc at -30 dBm
Harmonic measurement accuracy
16 MHz to 3 GHz
3 GHz to 6 GHz Option 006
Harmonic measurement dynamic range
6
-40 dBc
(output = -10 dBm,
input <-15 dBm)
0 dBm
≥20 dB RL
≥24 dB RL
≥19 dB RL
≥15 dB RL
6
±1.0 dB,
±2.0 dB
6
6
6
6
±1.5 dB
±3 dB
12

Advertisement