Hardware Reference
C613-03020-00 REV K
Figure 32: Example output from the SHOW INSTALL command
Install
Release
------------------------------------------------------------
Temporary
-
Preferred
flash:load\86s-210.rez
Default
EPROM (86s-2.1.0)
------------------------------------------------------------
Current install
------------------------------------------------------------
Preferred
flash:load\86s-210.rez
------------------------------------------------------------
Install history
------------------------------------------------------------
No Temporary install selected
Preferred install selected
Preferred release successfully installed
------------------------------------------------------------

Troubleshooting EPROM Installation

If the switch fails to reboot or functions incorrectly, then the most likely cause is
that there is a problem with the way the boot EPROMs were installed. Repeat
the installation procedure, checking:
That the boot EPROMs are in the correct locations and oriented
correctly (using the relevant location diagram as a guide).
For bent pins. These should be carefully straightened.
If the switch still fails to reboot, replace the new boot EPROMs with the
original set and contact your Authorised Allied Telesis distributor or reseller.