EM-70 PLASTER/MORTAR MIXER — SHUT-DOWN PROCEDURES
Stopping the Mixer (Gasoline Engine)
Place the belt slip lever in the start/stop position
1.
(Figure 20).
Push the main start/stop switch (Figure 15) inward to
2.
stop the engine.
3.
Turn the fuel shut-off valve to the OFF position.
4.
Disconnect the spark plug.
5.
Clean mixer as referenced in the maintance section of
this manual.
It is recommended that the mixer's
NOTE
Start/Stop switch be used to stop
the engine after every use.
Doing this will verify that the switch is working properly and
presents no danger to the operator.
DANGER
DANGER
DANGER
DANGER
DANGER
NEVER disable or disconnect the start/stop switch. It is
provided for operator safety. Serious Injury may result if
it is disabled, disconnected or improperly maintained.
EM-70 PLASTER/MORTAR MIXER — OPERATION MANUAL — REV. #1 (008/10/04) — PAGE 27
DO NOT Disconnect
the Start/Stop Switch
Stopping the Mixer (Electric Motor)
Place the electric motor's ON/OFF switch (Figure 7) in
1.
the OFF position.
2.
Disconnect the electric motor's extension cord from its
power source.
3.
Clean mixer as referenced in the maintance section of
this manual.