If you run into a problem, refer to the troubleshooting table below.
Symptom
Refrigerator or freezer is not
cold enough
The refrigerator does not work
on 120V AC
RM1350, RM1350 IM &
RM1350 WIM
The refrigerator does not work in
gas operation mode
Odors from fumes
If the problem persists and the refrigerator is still not working properly, contact your nearest service Center. state the problem,
model, product- and serial-number. These details are stated on the data label inside the refrigerator compartment.
WaRnInGS
For information about warnings, refer to the following table. The messages are displayed flashing (alternating between
temperature and the message).
WaRnInGS
InFoRmatIon
RM1350, RM1350 IM & RM1350 WIM
LP
Gas ignition failed. Gas bottle empty, the manual valve(s) are closed or burner jet clogged.
tRoUblEShootInG
chEck/REmEdIal actIon
•
Check the thermostat and adjust if necessary.
•
Is there a power failure?
•
Is the refrigerator level? (Because of its operation it is important to keep an
absorption refrigerator level.)
•
has the overheating protection been triggered or not?
•
has the door been closed properly? If not it can cause the inside temperature to rise.
•
heavy frost build-up on evaporator fins? To prevent frost buildup do not leave the unit's
door open longer than necessary.
•
Overpacked refrigerator? The unit will have to work harder if the refrigerator is stuffed
and results in higher cabinet temperatures. Arrange the food in the unit to allow for free
air circulation.
•
Is the plug firmly connected to the receptacle? Is the socket switched on? Check the
receptacle by plugging in another appliance.
•
Are the fuses intact for the AC supply and control system?
•
Gas bottle empty?
Change the gas bottle
•
Air in the gas pipe?
see
REFRIGERATOR OVERVIEw > PuRGING AIR FROM ThE LINEs
•
Is the burner dirty, damaged or not properly located under the flue tube?
•
Is the burner jet clogged?
•
Is the flue baffle inserted properly in the flue tube?
•
Is the LP gas pressure low at burner?
set the main regulator to regulate the pressure so it does not drop below 11 inches water
column at pressure tap.
•
Dislocated burner
•
Damaged burner
•
Dirty flue tube
- 1 -