AEG HG654320 User Manual page 13

Hob
Hide thumbs Also See for HG654320:
Table of Contents

Advertisement

2.
The supply system is equipped with
an efficient earth connection in com-
pliance with the current standards
and regulations
3.
The outlet or omnipolar switch used
for connection is easily accessible
with the appliance installed.
The appliance is supplied with a 3 core
flexible powercable with a 3 amp plug. If
it is necessary to change the fuse, use a
3 amp ASTA-approved (BS 1362) fuse.
A
E
A)
Green and Yellow
B)
3 amp fuse
C)
Brown
D)
Cord clamp
E)
Blue
The wires in the cord are coloured as fol-
lows:
Green and yellow
Blue
Brown
Replacement of the connection cable
1.
Connect the green and yellow
(earth) wire to the terminal which is
marked with the letter 'E', or the
earth symbol
and yellow.
B
C
D
- Earth
- Neutral
- Live
, or coloured green
2.
Connect the blue (neutral) wire to
the terminal which is marked with
the letter 'N' or coloured blue.
3.
Connect the brown (live) wire to the
terminal which is marked with the
letter 'L'. It must always be connec-
ted to the network phase.
There must be no cut or stray strands of
wire present. The cord clamp must be
correctly attached to the outer sheath.
To replace the connection cable
use only H05V2V2-F T90 or
equivalent type. Make sure that
the cable section is applicable to
the voltage load and the working
temperature. The yellow/green
earth wire (B) must be approxi-
mately 2 cm longer than the live
and neutral wire (A).
WARNING!
A cut off plug inserted into a 13
amp socket is a serious safety
(shock) hazard. Ensure that the
cut off plug is disposed of safely.
The replacement of electric cable
must be carried out exclusively
by the service force centre or by
personnel with similar competen-
cies, in accordance with the cur-
rent regulations.
ENGLISH