Z-Sus Board - LG 42PG20 Training Manual

Plasma display panel
Hide thumbs Also See for 42PG20:
Table of Contents

Advertisement

CIRCUIT DeSCRIPTIONS

Z-SUS BOARD

4
Provides the SUSTAIN PULSE and ERASE PULSE for generating SUSTAIN discharge in
the panel by receiving Drive signals from the Y/Z-Sus board. This waveform is supplied
to the panel through FPC (Flexible Printed Circuit (Z). Z-Bias is a "DC" adjustment. The
2
effects of this adjustment can be observed on the scope looking at the Z-Sus output.
This Waveform is just for reference to observe the effects of Zbz adjustment. Note: The
P
Vzb Adjustment is a DC level adjustment.
G
2
0
42
PDP Training - Fall 2008
Z-Drive Wavefrorm
100 us/Div
"Y-Sus" P801 to "Z-Drive" P1
Pin
Label
Standby
1
+Vs
2
Gnd
Gnd
3
ZSUS
4
Gnd
Gnd
5
ZSUS
6
Gnd
Gnd
7
ZSUS
8
Gnd
Gnd
9
ZSUS
10
Gnd
Gnd
11
ZSUS
Probe Test Point
(Vzb) Z-Bias VR905
Run
Diode Mode
0V
*194V
Open
Gnd
Gnd
0V
70.46V
Open
Gnd
Gnd
0V
70.46V
Open
Gnd
Gnd
0V
70.46V
Open
Gnd
Gnd
0V
70.46V
Open
Gnd
Gnd
0V
70.46V
Open