CIRCUIT DeSCRIPTIONS
could be caused by a failure on the SMPS or a circuit
using these voltages. A resistance check should narrow
4
the possible failures quickly.
POWER SUPPlY STATIC TEST
2
This test can confirm the proper operation of the SMPS
without the need to exchange the board.This Power
P
Supply can operate in a No Load State. This means that
by applying AC power to SC101 and all other plugs
disconnected, this power supply will function. Simply
G
removing P813 (Lower Right Hand Side of the board),
will cause the "AUTO" Pin 22 to go high from its normal
low state allowing the Power Supply to go to full power
2
on mode when AC Power is Supplied. Be careful after this
test and make sure the VA and VS lines have discharged before reconnecting the supply
0
cables.
If the Y-Sus and Z-Sus boards are working normal, "Display Panel Reset" will be visible
when the SMPS comes up to full power. Shorting the Auto Pattern Gen. test points at
this time should result in test patterns on the screen.
vS/vA ADJUSTMENTS
This Power Supply will come up and run with "no" load (P812 pulled). Pull P813, apply AC
power, and the Power Supply starts. Y-Sus/Z-Sus runs "Yes" both Y and Z waveforms.
Model : PDP42G1####
||||||||||||||||||||||||||||||||||||||||||||||||||||
801K542G1008000 .AKAZBED
Voltage Setting :DC 5V Va:65V/ Vs:195V
NA / -190 / 140 / NA / 100
24
PDP Training - Fall 2008
16V
16V
2
2
4
4
Gnd
Gnd
6
6
NC
NC
8
8
Gnd
Gnd
10
10
5VSTB
5VSTB
5VSTB
5VSTB
12
12
14
14
Gnd
Gnd
16
16
Gnd
Gnd
18
18
AC Det
AC Det
20
VS_ON
VS_ON
Auto Gnd
Auto Gnd
22
22
Vs TP
Va TP
P812
Pin 1 or 2
Pin 5 or 6
Use Full White Raster
15V
15V
1
1
3
3
Gnd
Gnd
5
5
NC
NC
7
7
Gnd
Gnd
9
9
5VSTB
5VSTB
11
11
5VSTB
5VSTB
13
13
Gnd
Gnd
15
15
Gnd
Gnd
17
17
5_V Det
5_V Det
19
19
RL_ON
RL_ON
M5V_ON
M5V_ON
21
21
P812

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents