Draining the Fuel Tank and Carburetor
1.Place a suitable gasoline container
below the carburetor.
2.Turn the fuel valve lever to the
OFF position, loosen the
carburetor drain bolt by turning 1
to 2 turns counterclockwise, and
drain the fuel from the carburetor.
3.Remove the sediment cup (see
page 42), and then turn the fuel
valve lever to the ON position and
drain the fuel from the fuel tank.
4.After all the fuel has drained into the container, tighten the carburetor
drain bolt securely.
5.Install the sediment cup and a new O-ring.
6.Turn the fuel valve lever to the OFF position.
Gasoline is highly flammable and
explosive.
You can be burned or seriously
injured when handling fuel.
• Stop the engine and keep heat,
sparks, and flame away.
• Handle fuel only outdoors.
• Wipe up spills immediately.
STORAGE
CARBURETOR DRAIN BOLT