CONTROL & FEATURES
Output Indicator
The output indicator (green) will remain ON during normal operating
conditions.
If there is a short circuit in a connected appliance or if the
TM
CycloConverter
unit overheats, the output indicator (green) blinks
and current to the connected appliance(s) will shut off. When this
happens, disconnect the appliance(s) and stop the engine to investigate
the problem.
Determine if the cause is a short circuit in a connected appliance or an
overheated CycloConverter unit. Correct the problem and restart the
engine.
If the output indicator (green) blinks again, consult your Honda
generator dealer.
The output indicator (green) may blink at intervals of 2.5 seconds,
depending on connected appliance(s) to the AC receptacles. It
indicates that the output voltage has dropped slightly. It does not
matter as long as the connected appliance(s) work properly.
OUTPUT INDICATOR (GREEN)
17