HP StorageWorks XP12000 Configuration Manual page 31

Disk array xp operating system hp-ux
Hide thumbs Also See for StorageWorks XP12000:
Table of Contents

Advertisement

Example
Installation
customer support for assistance with the HP 9000 system or the
HP-UX operating system.
3. Enter the device data for each disk array device in a table. See "Path
worksheet"
on page
4. Construct the device file name for each device, using the device
information, and enter the file names in your table. Use the following
formula to construct the device file name:
cxtydz
where
x = SCSI bus instance number
y = SCSI target ID
z = LUN
c stands for controller, t stands for target ID, and d stands for device.
The numbers x, y, and z are hexadecimal.
SCSI bus
instance number
00
00
5. Verify that the SCSI TIDs correspond to the assigned port address for
all connected ports (see mapping tables on page 63 in Appendix B, for
values). If so, the logical devices are recognized properly.
If the logical devices are not recognized properly:
• Check the AL-PA for each port using the LUN Manager software.
• If the same port address is set for multiple ports on the same loop
(AL with HUB), all port addresses except one changed to another
value, and the relationship between AL-PA and TID does not
correspond to the mapping given in Appendix B (page 63), set a
62.
Hardware path SCSI TID
14/12.6.0
6
14/12.6.1
6
LUN
File name
0
c6t0d0
1
c6t0d1
33