F. Tools and Supplies Needed
Before beginning the installation be sure the following tools
and building supplies are available:
Reciprocating saw
Pliers
Hammer
Phillips screwdriver
Flat blade screwdriver
Plumb line
Level
1/2-3/4 in. length, #6 or #8 self-drilling screws
Misc. screws and nails
G. Typical Fireplace Components
Hearth Molded brick panel
-
Molded brick panel kit must be installed, but is sold
separately
Grate Assembly
Transition Assembly (14-11 in.)
-
Must be installed immediately on top of the fireplace
Outside Air Kits
-
Duct must be installed, but sold separately
Framing material
Non-combustible sealant
Gloves
Framing square
Electric drill and bits
Safety glasses
Tape measure
Heatilator • Birmingham BIR42-B • 4059-681• 11/11
H. Inspect Fireplace and Components
WARNING! Risk of Fire and/or Explosion! Damaged
parts could impair safe operation. DO NOT install dam-
aged, incomplete or substitute components. Keep fireplace
dry.
Remove fireplace from pallet.
Remove fireplace and components from packaging and
inspect for damage.
Remove the transition, hearth molded brick panel, screens
and grate from inside the unit.
Vent system components, doors, remaining molded brick
panels and mortar are shipped in separate packages.
Report to your dealer any parts damaged in shipment.
Read all the instructions before starting the installation.
Follow these instructions carefully during the
installation to ensure maximum safety and benefit.