Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Contact your dealer with questions on installation, operation, or service.
NOTICE: DO NOT discard this manual!
Model(s):

WOODBURNING FIREPLACE

Installation and service of this fi replace should be
performed by qualifi ed personnel. Hearth & Home
Technologies recommends NFI certifi ed profes-
sionals, or technicians supervised by an
NFI certifi ed professional.
Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13
Owner's Manual
Operation and Care
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• DO NOT overfi re. Overfi ring will void your
warranty.
• Comply with all minimum clearances to com-
bustibles as specifi ed. Failure to comply may
cause house fi re.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
WARNING
Fire Risk.
For use with solid wood fuel only.
Other fuels may overfi re and generate poisonous
gases (i.e. carbon monoxide).
1

Advertisement

Table of Contents
loading

Summary of Contents for Heatilator BIR36-B

  • Page 1: Woodburning Fireplace

    • Keep clothing, furniture, draperies and other fl ammable materials away. WOODBURNING FIREPLACE WARNING Installation and service of this fi replace should be performed by qualifi ed personnel. Hearth & Home Technologies recommends NFI certifi ed profes- Fire Risk. sionals, or technicians supervised by an For use with solid wood fuel only. NFI certifi ed professional. Other fuels may overfi re and generate poisonous gases (i.e. carbon monoxide). Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 2: Table Of Contents

    8. Chimney Fire B. General Operating Parts 1. Flue Damper 2. Outside Air 3. Glass Doors C. Fuel 1. Hardwood vs. Softwood 2. Moisture content 3. Seasoning 4. Storing Wood 5. Burning Process 6. Creosote Formation D. Processed Solid Fuel Firelogs E. First Fire F. Lighting Instructions Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 3: Welcome

    IF INSTALLATION OR OPERATING INSTRUCTIONS ARE MISSING DECORATIVE GAS APPLIANCE IN THE FIREPLACE, CONTACT: HEARTH & HOME TECHNOLOGIES, ADJUST DAMPER TO THE FULLY OPEN POSITION. 7571 215th Street West, Lakeville, MN 55044 Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 4: Limited Lifetime Warranty

    2 years Factory-installed blowers Molded refractory panels 3 years Firepots and burnpots 5 years 1 year Castings and baffles Manifold tubes, 7 years 3 years HHT chimney and termination 1 year Burners, logs and refractory years Limited 3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645F 02-18-13 Page 1 of 2 Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 5 This warranty is void if: • The appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals. Over-firing can be identified by, but not limited to, warped plates or tubes, rust colored cast iron, bubbling, cracking and discoloration of steel or enamel finishes. • The appliance is subjected to prolonged periods of dampness or condensation. • There is any damage to the appliance or other components due to water or weather damage which is the result of, but not limited to, improper chimney or venting installation. LIMITATIONS OF LIABILITY: • The owner’s exclusive remedy and HHT’s sole obligation under this warranty, under any other warranty, express or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above. In no event will HHT be liable for any incidental or consequential damages caused by defects in the appliance. Some states do not allow exclusions or limitation of incidental or consequential damages, so these limitations may not apply to you. This warranty gives you specific rights; you may also have other rights, which vary from state to state. EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645F 02-18-13 Page 2 of 2 Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 6: Product Specific And General Information

    • DO NOT install unvented gas logs. This fireplace has been tested and listed for use with • Damper must be locked open. the optional components specified in this manual. These • Gas flame may generate fumes. optional components may be purchased separately and installed at a later date. Heatilator is a registered trademark of Hearth & Home Technologies. Warning! Risk of Fire! For use with solid wood fuel only. Other fuels may overfire and generate poisonous gases (i.e. carbon monoxide). Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 7: Important Safety And Operating Information

    63-3/4 in. (1619 mm) Clear Space Bottom of Fireplace to 48 in. (1219 mm) Lower Edge of Clear Space Mantel or Trim Front of Fireplace 24 in. (610 mm) Clear Space Sides of Fireplace Opening Figure 3.1 Clear Space Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 8: Grate

    If doors are left partly open, gas and flame may be drawn out of the fireplace opening. Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 9: General Operating Parts

    re or injury. Outside Air Control Handles Flue Damper Turn handle to unlock, UP to Open pull towards the inside of the fireplace to open. DOWN to Close Reverse steps to close & lock. Figure 3.2 General Operating Parts Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 10: Flue Damper

    Other methods may be required if FULLY CLOSED PARTLY CLOSED more air is needed. CORRECT INCORRECT The outside air inlet should be in the fully opened posi- tion during operation of the fi replace. Close the inlet to prevent cold drafts when the fi replace is not being used. CAUTION! Outside air control handle may be warm. Adjust before lighting fi re. Figure 3.3 Operating Positions of Bi-fold Doors Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 11: Fuel

    Soft woods Hard woods • Douglas Fir • Oak • Pine • Maple • Spruce • Apple • Cedar • Birch • Poplar • Aspen • Alder Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 12: Seasoning

    • Store wood under cover, such as in a shed, or covered with a tarp, plastic, tar paper, sheets of scrap E. First Fire plywood, etc., as uncovered wood can absorb water Before lighting your first fire in the fireplace, make certain from rain or snow, delaying the seasoning process. that: Avoid covering the sides and ends completely. Doing so may trap moisture from the ground and impede • refractory is in place air circulation. • all labels have been removed Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 13: Lighting Instructions

    WARNING! Risk of Fire! Keep combustible materials, gasoline and other flammable vapors and liquids clear of the fireplace. DO NOT: • store flammable materials close to the fireplace • use gasoline, lantern fuel, kerosene, charcoal lighter fluid or similar liquids to start or “freshen up” a fire in this fireplace. Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 14: Maintenance And Service

    • Confirm that termination cap remains clear and unobstructed. • Inspect for blockages such as bird nests, leaves, etc. • Inspect for corrosion or separation. • Inspect for creosote and remove as needed, at least every two months during the heating season. • Inspect the system at the fireplace connection and at the chimney top. In the event of a chimney fire, Hearth & Home Tech- nologies recommends replacement of the chimney and inspection of the adjacent structure to the provisions of NFPA Level III inspection criteria. Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 15: Creosote (Chimney) Cleaning

    Screw Slip Section TR11/TR11T ST1175 TCT1175 Round Termination Cap Square Termination Cap Terra Cotta DTO/DTS Series Termination Cap Termination Cap Figure 4.1 Chimney & Termination Cap Cleaning Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 16: Grate

    • If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled. F. Molded Brick Panels Frequency: After each ash removal Homeowner The panels should be replaced if • Cracks exceed ¼ inch (6 mm) in width • Metal is exposed behind a panel • Large pieces of panel fall out Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 17: Troubleshooting

    Wood condition is too wet, too large Use dry, seasoned wood (refer to wood fuel section). Bed of coals not established before Start with paper & kindling to establish bed of coals (refer adding wood to starting fire section). Flue blockage such as birds’ nests Have chimney inspected for creosote and cleaned by a or leaves in termination cap certified chimney sweep. Down draft or negative pressure Do not use exhaust fans during start-up (refer to negative Competition with exhaust devices pressure section). Open window below the fireplace towards the wind. Fire burns too fast Extremely dry or soft wood Mix in hardwood. Mix in less seasoned wood after fire is established (refer to wood fuel section). No glass doors Add glass doors to slow down air flow. Overdrafting Check for correct vent height; too much vertical height creates overdrafting. Check location of vent termination (refer to chimney assembly section). Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 18: Faqs

    Contact your dealer for additional informa- If the fire is hard to start and smoke spills out of the fire- tion regarding operation and troubleshoot- place, or you find it difficult to establish and maintain a ing. Visit www.heatilator.com to find a moderately high burn rate, then the flue draft is too low and corrective measures must be taken. dealer. Be sure you have air available for combustion and that your firewood is dry and well seasoned. Build your fires properly and according to the instructions given in op- Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 19 (furnace, fan, Unsealed dryer, etc.)? can lights? Overhead fan operating? Creosote buildup in flue? Air register from furnace near fireplace? Doors opening and closing? Outside air Window closed Combustion closed? for start-up? air control Figure 5.1 Factory-built Fireplaces: Troubleshooting Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 20: Reference Materials

    4059-053 Screen Rod Qty 2 req 4059-512 Screen Rod Clips Qty 2 req 4059-111 Firescreen Assembly 4059-054 Grate Assembly GR30 Hearth Refractory SRV4059-693 Mortar 10 Lb Bucket MMMORTR Outside Air Hood Qty 2 req 4059-051 Starting Collar 4059-137 Owners Manual 4059-710 Installation Manual 4059-709 Additional service parts on following page. 11/13 Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 21: Service Parts

    Depot ITEM DESCRIPTION COMMENTS PART NUMBER Traditional Refractory MMTB36-B Left Panel SRV4059-652 Back Panel SRV4059-659 Right Panel SRV4059-653 Herringbone Refractory MMHB36-B Left Panel SRV4059-656 Back Panel SRV4059-661 Right Panel SRV4059-657 Refractory Fastener Pack 4059-668 Contains: 8 #6 X 1 1/2" Panhead screw, 3/32" Drill Bit, 8 Clips, Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 22: Accessories

    1. Doors DFG4036 Series Glass Bi-fold Doors DFS4036 Series Mesh Cabinet-Style Doors (optional) (optional) 2. Gas Inserts 3. Gas Log Sets 4. Gas Log Lighters 5. Wood-burning Inserts Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 23 This page intentionally left blank. Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...
  • Page 24: Contact Information

    6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884,7047962, 7216645, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Printed in U.S.A. - Copyright 2012 Heatilator • Birmingham 36-B OWNERS MANUAL • 4059-710 • Rev F • 11/25/13...

This manual is also suitable for:

Bir42-bBirmingham 36-b

Table of Contents