TONIC FRONT
A
B
Figure 13.14. Dimensions of Tonic Decorative Front.
Table 1. Dimensions of Tonic Decorative Front.
A
Top of decorative front to bottom of appliance.
B
Bottom of decorative front to bottom of appliance.
C
Inside dimension of decorative front (width).
D
Outside dimension of decorative front (width).
E
Inside dimension decorative front (height).
F
Outside dimension of decorative front (height).
This appliance requires field-installation of heat shield(s) on
the firebox glass frame. These shields function to manage
convective heat transfer during blower operation. These
shields are critical to the performance and reliability of the
appliance because they prevent overheating of gas control
components.
For installation finished with the Martini decorative front, a
single lower glass heat shield is installed in the bottom of the
glass frame. This shield will be installed prior to installing the
decorative surround and glass. See Figure 13.15. It is also
critical that the required air space is maintained between the
underside of the Martini surround and the adjacent finishing
materials. See Figure 13.16.
For installations finished with the Tonic decorative front, both
an upper and lower glass heat shields are installed in the top
and bottom of the firebox glass frame. These will be installed
prior to installing the framed mesh and the Tonic surround.
See Figures 13.15 and 13.16.
WARNING! Risk of Valve / Control Damage! This appliance
requires field-installation of heat shields onto the firebox glass
frame. Do not operate this appliance without the specified heat
sheild(s).
E F
C
D
26-3/8 in.
(670 mm)
6-7/8 in.
(175 mm)
39 in.
(991 mm)
44-1/2 in.
(1.13 m)
12-7/8 in.
(327 mm)
19-1/2 in.
(495 mm)
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12
UPPER GLASS HEAT SHIELD
(TONIC ONLY)
LOWER GLASS HEAT SHIELD
(MARTINI & TONIC FRONTS)
Glass Lip Heat Shield seats in glass frame.
Retain top upper glass heat shield with tinnerman clip on
each side of glass frame.
Figure 13.15 Glass and Heat Shield - Martini and Tonic
Figure 13.16 Martini Front Gap
Gap between Tonic front and Tonic glass lip. This
gap is for cool air flow when fan is running.
Figure 13.17Tonic Front Gap
Gap below Martini front
must not be covered - it
is for cool air flow when
the fan is running.