Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling firestops.
• ALWAYS maintain specified clearances around venting and firestop systems.
• Install wall shield and ceiling firestops as specified.
Failure to keep insulation or other material away from vent pipe may cause fire.
Top Vent - Horizontal Termination
Venting with 1 elbow
V Minimum
H
90 Elbow
305 mm (1 ft.)
914 mm (3 ft.)
457 mm (1.5 ft.)
1067 mm (3.5 ft.)
610 mm (2 ft.)
1.52 m (5 ft.)
762 mm (2.5 ft.)
1.85 m (6 ft.)
914 mm (3 ft.)
2.13 m (7 ft.)
1066 mm (3.5 ft.)
3.05 m (10 ft.)
1.2 m (4 ft.)
4.6 m (15 ft.)
H Max. =4.6 m (15 ft.)
V + H Max. = 12.2 m
Figure 7.3
Maximum
1
457 mm
H
1
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12
WARNING
Note: All appliances that will burn butane must have
a 10 in. (254 mm) vertical section of pipe
before any other venting.
Note: Use SLP Series
components only.
V