Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be
used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm)
the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a
DVP-HSM-B will be required.
15-1/8 in.
(384 mm)
(305 mm)
8-1/8 in.
(206 mm)
15 in.
(381 mm)
SLP90
Figure 16.4 SLP Series Vent Components
64
8 in.
(203 mm)
12 in.
SLP-TRAP
Horizontal Termination Cap
13 in.
(330 mm)
CAUTION: THE SLP-HRC-SS AND SLP-HRC-ZC-SS
TERMINATION CAPS ARE NOT APPROVED FOR
USE WITH PROPANE (LP) FUEL. May lead to ele-
vated glass temperature that may cause tempered
glass breakage.
HORIZONTAL TERMINATION CAP
15-1/2 IN.
394 mm
DVP-FBHT
SL-2DVP
Heatilator • RAVE4013I-C • 2293-900 Rev. i • 4/14
Heat
Shield
Term Cap
Max
Effective
Trap1
Length
Trap2
Effective Length
5-3/4 to 8-3/8 in.
5-1/2 in.
146 to 213 mm
140 mm
87°
SLP-HRC-SS
SLP-HRC-ZC-SS
7 IN.
178 mm
Minimum
Maximum
Effective Length
Effective Length
3-1/8 in.
4-3/4 in.
79 mm
121 mm
5-1/4 in.
9-1/4 in.
133 mm
235 mm
8-3/8 in.
213 mm
10-1/2 in.
267 mm
10-7/8 in.
276 mm
12 IN.
305 mm
DVP-FBHT