Mantel And Wall Projections - Heatilator RAVE4013I-C Owner's Manual

Gas fireplace
Table of Contents

Advertisement

B. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.)
Failure to comply could cause fi re.
Note: For non-combustible fi replace fi nish material (marble,
stone, etc) specifi cations refer to Section 13.C.
Combustible Mantels
1/2 IN.
Thick Wall
Sheathing
14 IN.
MIN.
Figure 13.4 Clearances To Combustibles Mantels Or Other
Combustibles Above Appliance
Non-combustible Mantels
1/2 IN.
Thick Wall
Sheathing
MEASUREMENT
FROM TOP OF
FIREPLACE
OPENING
See Dimension T on
Appliance Dimension
Diagram (Figure 16.1).
Figure 13.5 Clearances To Non-Combustible Mantels Or Other
Non-Combustibles Above Appliance
12 IN.
MAX.
MEASUREMENT
FROM TOP OF
FIREPLACE
OPENING
See Dimension T on Appliance
Dimension Diagram (Figure 16.1).
12 IN.
MAX.
14 IN.
MIN.
1 IN.MIN.
4 IN.
MAX.
Heatilator • RAVE4013I-C • 2293-900 Rev. i • 4/14
Mantel Legs Or Wall Projections Extending Past The Face
Of The Fireplace (Combustible or Non-Combustible)
6 IN.
MINIMUM
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 16.1).
Figure 13.6 Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
7 IN.
MINIMUM
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 16.1).
Figure 13.7 Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
Note: Clearance from opening
to perpendicular wall.
3 FT. MAXIMUM
Note: Clearance from opening
to perpendicular wall.
UNLIMITED
53