Freeze Protection - Master Spas Legend LSX700 Owner's Manual

Master spas legend series and down east spas owner's manual
Hide thumbs Also See for Legend LSX700:
Table of Contents

Advertisement

MASTER SPA – LEGEND SERIES – LSX 557 - CONTROLS
Light
Press the "Light" button to turn the light on and off. If left on, the light automatically turns off after
4 hours.
L.e.d. Light
Press the "Light" button to turn the light on and off. If you wish to change the "function" of the lights,
turn the lights off, then on within 5 seconds. If you wish to leave the lights in the same "function"
setting for the next use, turn the lights off and do not turn back on for at least 5 seconds.
mode
Mode is changed by pressing the "Warm" or "Cool" button, then pressing the "Mode" button.
Standard mode
is programmed to maintain the desired temperature. Note that the last measured spa
temperature displayed is current only when the pump has been running for at least 2 minutes. "St" will
be displayed momentarily when you switch into Standard mode.
Economy mode
heats the spa to the set temperature only during filter cycles. "Ec" will display solid
when the temperature is not current, and will alternate with the temperature when the temperature is
current.
Sleep mode
heats the spa to within 20˚F /10˚C) of the set temperature only during filter cycles. "SL"
will display solid when the temperature is not current, and will alternate with temperature when
temperature is current.
preset filter cycles (if configured)
Your spa comes standard with a 24 hour circulation pump that filters and maintains heat
as programmed/configured.

freeze protection

If the temperature sensors detect a drop to below 44˚F /6.7˚C within the heater, the pump automatically
activates to provide freeze protection. The equipment stays on until 4 minutes after the sensors detect
that the spa temperature has risen to 45˚F /7.2˚C or higher. In colder climates, an optional additional
freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard
sensors. Aux freeze sensor protection acts similarly except with the temperature thresholds determined
by the switch and without a 4-minute delay in turnoff. See your dealer for details.
DO NOT DIVE.
44