SPA WATER MAINTENANCE - Schedule
For Spas without Eco Pur™ Filtration System
day One
1.
Test and adjust total alkalinity if necessary to between 80 to 150 ppm using the pH / alkalinity
increaser or decreaser 1oz. at a time. Wait 15 minutes, retest and adjust if necessary. The pump
should be running on high speed during this time with the air controls closed.
2.
Test and adjust pH, if necessary, to within the range of 7.2 to 7.8 using the pH / alkalinity increaser
or decreaser, 1/2oz. at a time. Wait 15 minutes, retest and adjust if necessary. The pump should be
running on high speed during this time with the air controls closed.
3.
Test and adjust sanitizer level. Add chlorine following label directions to maintain a free chlorine
level of 1 to 3 ppm. If using bromine, adjust feeder to maintain a total bromine level of 3 to 5
ppm. Add bromine tablets to the dispenser if necessary, following label directions.
4.
Add a water clarifier following label directions. If the spa is equipped with an ozone unit, we
recommend adding an enzyme product in place of the clarifier, following the label directions.
5.
Use a small amount of defoamer only if necessary.
day Two Skip
day Three
1.
Test and adjust total alkalinity, if necessary, to between 80 and 150 ppm using the pH / alkalinity
increaser or decreaser, 1oz at a time. Wait 15 minutes, retest and adjust if necessary. The pump
should be running on high speed during this time with the air controls closed.
2.
Test and adjust the pH, if necessary, to within the range of 7.2 to 7.8 using the pH / alkalinity
increaser or decreaser, 1/2oz at a time. Wait 15 minutes, retest and adjust if necessary. The pump
should be running on high speed during this time with the air controls closed.
3.
Test and adjust sanitizer level. Add chlorine following label directions to maintain a free chlorine
level of 1 to 3 ppm. If using bromine, adjust feeder to maintain a total bromine level of 3 to 5
ppm. Add bromine tablets to the dispenser if necessary, following label directions.
4.
Add sequestering chemical, following label directions for maintenance.
5.
If necessary, clean water line with a spa general purpose cleaner or enzyme product.
6.
Use a defoamer only if necessary.
day four Skip