1. Pull the wire leads, coming from the end of the downrod, and
the supply wires through the open side of the hanger bracket.
2. Position the Receiver in the ceiling cover so that the flat side of
the receiver faces up and the open portion of the receiver is to
the right, as shown.
3. Using wire connectors (supplied), make wiring connections as
follows:
a. Connect the green ground wires from the hanger bracket
and the hanger ball to the supply ground wire (bare or
green).
b. Connect the white fan to the white supply wire.
c. Connect the black fan wire to the black supply wire.
1. After connections have been made, turn leads upward and
carefully push leads into the outlet box, with the white and
green leads on one side of the outlet box and the black, blue and
yellow leads on the other side of the outlet box.
2. Lift the ceiling cover up to the threaded studs and turn until
studs protrude through the holes in the ceiling cover.
3. Secure the ceiling cover in place by sliding lock-
washers over the threaded studs and installing the two knurled
knobs (supplied). Tighten the knurled knobs securely until the
ceiling cover fits snugly against the ceiling. Your fan is now
wired to be controlled using the remote control transmitter.
Programming, High Speed Conditioning and Operation of Remote Control
1. The receiver must be programmed within 2 minutes of restoring
electricity to the fan. Program the receiver code by pushing and
holding down the remote control OFF button for 3-5 seconds.
The ceiling fan lights will blink when the receiver has completed
programming.
2. If programming fails, shut off and turn on the electricity at the
wall switch to reset the receiver. Repeat Step 1 above.
3. If programming continues to fail, change the remote code and
repeat Steps 1 and 2 as necessary until the fan successfully
completes the programming procedure.
NOTE: Fan installation must be completed, including the
installation of the fan blades, before testing the remote control.
4. Your SR600 Fan/Light remote control has full control of your
fan speed, air flow direction and light intensity.
NOTE: The following procedure must be completed.
5. Operate the fan at high speed for 2 minutes. Reverse the fan
and operate on high speed 2 additional minutes.
* For additional installation review full instructions on
page 13.
EMERSON QUICK START GUIDE
Wiring Ceiling Fan
Installation of Ceiling Cover
(page 11)
SUPPLY
BLACK FAN WIRE
GROUND
WIRE
LISTED
WIRE
CONNECTOR (3)
GREEN WIRE
(GROUND) FROM
HANGER BRACKET
GREEN WIRE
(GROUND) FROM
HANGER BALL
(page 12)
THREADED STUD
KNURLED KNOB
4
NOTE: CEILING COVER
OMITTED FOR CLARITY.
WHITE SUPPLY
(NEUTRAL)
WHITE FAN
WIRE
BLACK SUPPLY (HOT)
THREADED
STUD (2)
CEILING COVER
LOCKWASHERS (2)
(pages 13 and 14)
ETL Model No.: CF955-3