Troubleshooting - Emerson CF955BS 03 Owner's Manual

54” ceiling fan
Table of Contents

Advertisement

!
WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER
BEFORE TROUBLE SHOOTING YOUR FAN.
AVERTISSEMENT : POUR VOTRE PROPRE SÉCURITÉ, COUPEZ L'ALIMENTATION
!
ÉLECTRIQUE AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR AVANT DE TENTER DE RÉPARER
VOTRE VENTILATEUR.
TROUBLE
1. Fan will not start.
2. Fan sounds noisy.
3. Fan wobbles
excessively.
4. All four lamps will not
illuminate.
Trouble Shooting
PROBABLE CAUSE
1. Fuse or circuit breaker blown.
2. Loose power line connections to the fan.
3. The remote control transmitter battery needs
replacement.
4. Fan/Light Remote Control is OFF.
5. Remote is not programmed.
1. Blades not attached to fan.
2. Screws securing fan flywheel to motor
hub are loose.
3. Screws holding blades to flywheel are loose.
4. Glass bowl loose.
5. Hanger bracket and/or ceiling outlet box is not
securely fastened.
1. Setscrew in motor coupling is loose.
2. Setscrew in hanger ball/downrod assembly is
loose.
3. Screws securing fan flywheel to the motor hub
are loose.
4. Screws securing the fan blades to the
flywheel are loose.
5. Hanger bracket and/or ceiling outlet box is not
securely fastened.
6. Fan blades out of balance.
1. Loose electrical connectors.
2. The 1.25 amp lamp fuse may have blown and
and needs replacement.
3. The remote control transmitter battery needs
replacement.
1.Check main and branch circuit fuses or circuit breakers.
2.Check electrical wire connections to fan in the ceiling
cover.
WARNING: Make sure main power is turned off.
!
AVERTISSEMENT : assurez-vous que le courant
!
secteur est coupé.
3.Check that the remote transmitter battery is in good
condition; the red indicator will illuminate when the key
pad buttons are depressed.
4.Turn ON the Fan/Light Remote Control.
5. Program the remote and receiver per the Owner's
Manual instructions.
1.Attach blades to fan before operating.
2.Check to make sure the screws which attach the
flywheel to the motor hub are tight.
3.Tighten screws securely.
4.Tighten the glass bowl securely.
5.Tighten the hanger bracket screws to the outlet box,
and/or secure outlet box.
1.Raise coupler cover and tighten the setscrew securely.
2.Tighten the setscrew in the hanger ball/downrod
assembly.
3.Check to be sure the screws which attach the
flywheel to the motor hub are tight.
4.Tighten screws securely.
5.Tighten the hanger bracket screws to the outlet box,
and/or secure outlet box.
6.Interchanging an adjacent (side-by-side) blade pair can
redistribute the weight and result in smoother operation.
1.Shut off the branch circuit electricity at the fuse box or
breaker panel and check the receiver electrical
connectors for proper installation.
WARNING: Make sure main power is turned off.
!
AVERTISSEMENT : assurez-vous que le courant
!
secteur est coupé.
2.Replace the 1.25 amp fuse with Emerson repair part
item 19. See page 5 and reverse the lower housing
installation instructions to gain access to the fuse holder.
3.Replace the 12 V battery; recommended replacement
12 V batteries are Duracell MN21, Eveready A23, and
GP23A.
16
SUGGESTED REMEDY
ETL Model No.: CF955-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cf955ww 03Cf955orb 03

Table of Contents