Emerson CF955BS 03 Owner's Manual page 12

54” ceiling fan
Table of Contents

Advertisement

How to Wire Your Ceiling Fan
WARNING
!
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.
AVERTISSEMENT
!
Effectuez une inspection pour vous assurer que toutes
les connexions sont bien serrées, y compris la
connexion de mise à la terre, et qu'aucun fil nu n'est
visible près des connecteurs, à l'exception du fil de
mise à la terre. Ne mettez pas le ventilateur en marche
avant que les pales ne soient à leur place. Ceci
causerait un fonctionnement très bruyant et risquerait
d'endommager le ventilateur.
4. Screw the two threaded studs (supplied) into the
tapped holes in the hanger bracket.
5. Lift the ceiling cover up to the threaded studs and
turn until studs protrude through the holes in the
ceiling cover (Figure 12).
6. Secure the ceiling cover in place by sliding
lockwashers over the threaded studs and installing
the two knurled knobs (supplied). (Figure 12.)
Tighten the knurled knobs securely until the ceiling
cover fits snugly against the ceiling and the hole in
the ceiling cover is clear of the downrod.
Installing Lamps and Glass Globe
1. Carefully position one of the GU24 fluorescent
bulbs (supplied) into the light fitter socket, aligning
the two pins on the bottom of the bulb into the
socket holes. Twist the bulb clockwise,
approximately 1/16 turn, to engage the bulb pins
into the light socket holes.
2. Install the remaining three GU24 fluorescent bulbs
in the same manner.
3. Place the glass bowl into the opening in the lower
housing assembly, aligning the three flat areas on
the top edge of the glass with the three raised
dimples on the lower housing assembly and turn
the glass bowl clockwise until it stops (Figure 13).
NOTE: periodically check that the glass bowl is
seated fully clockwise in the lower housing
assembly.
THREADED STUD
KNURLED KNOB
Figure 12
!
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.
AVERTISSEMENT
!
Pour ne pas risquer d'incendie ou de choc électrique,
assurez-vous que les fils électriques sont
complètement à l'intérieur du boîtier de prises de
courant et qu'ils ne sont pas pincés entre le revêtement
de plafond et le plafond.
FLAT AREA
OF GLASS BOWL
Figure 13
12
(continued)
CEILING COVER
LOCKWASHERS (2)
WARNING
RAISED DIMPLES OF
LIGHT KIT HOUSING
FLOURESCENT
LAMP PLUG (4)
ETL Model No.: CF955-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cf955ww 03Cf955orb 03

Table of Contents