Specifications - Omega EWS-RH User Manual

Relative humidity/temperature transmitter
Table of Contents

Advertisement

EWS-RH
Relative Humidity/Temperature Transmitter
Relative Humidity Specifications
Range:
Accuracy @ 25°C:
Repeatability:
Temp. Compensation Range:
Output:
Power:
Max Loop Resistance:
RH Time Constant:
Sensor Type:
Temperature Specifications
Range:
Accuracy @ 25°C
In Still Air:
In Moving Air:
Note: Not recommended for fast moving air applications.
Repeatability:
Output :
Temp. Time Constant:
Power:
Max Loop Resistance:
Sensor Type:
General Specifications
Enclosure Material:
Dimensions:
Weight:
8
5-95% (non-condensing)
From 5-20%, ± 4% RH
From 20-80%, ± 3% RH
From 80-95%, ± 4% RH
± 1% RH
5 to 140°F (-15 to 60°C)
4-20 mA or 1-5 Vdc (scaled for 0 to
100% RH)
8-24 Vdc @ 20mA
Ohms = (V supply - 8V)/.02 A
100 sec., from 20-90%, 60 sec from
90-20%
Thin Film Polymer Capacitor
5 to 140°F (-15 to 60°C)
± 1.2°F (0.7°C) @ 25°C
± 2.5°F (1.4°C) across full range
± 2.5°F (1.4°C) @ 25°C
± 3°F (1.7°C) across full range
± 0.5°F (0.3°C)
4-20 mA or 1-5 Vdc (scaled across
range)
(for 63.2% response)
9 sec. in moving air (1 M/sec.),
30 sec. in still air
8-24 Vdc @ 20 mA
Ohms = (V supply - 8V)/.02 A
Solid State
Acrylonitrile Butadiene
79 x 54 x 45mm (3.12 L x 2.12 W x
1.78" H)
54 g(.12 lb)

Hide quick links: