Empire Comfort Systems VFP32FB2DL-3 Installation Instructions And Owner's Manual
Empire Comfort Systems VFP32FB2DL-3 Installation Instructions And Owner's Manual

Empire Comfort Systems VFP32FB2DL-3 Installation Instructions And Owner's Manual

Universal firebox for all vent-free log sets

Advertisement

Quick Links

The Breckenridge
Premium Vent-Free Universal Fireboxes
ANSI z21.91 ventless fireplace enclosures for gas fired Dec-
orative Type unvented room heaters
wArNINg: If the information in these instructions are
not followed exactly, a fire or explosion may result caus-
ing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appli-
ance.
— whAT TO DO If yOu SMeLL gAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
DO NOT ATTeMpT TO MODIfy Or ALTer The
cONSTrucTION Of The fIrebOx Or ITS cOMpO-
NeNTS. ANy MODIfIcATION Or ALTerATION Of
cONSTrucTION MAy vOID The wArrANTy Of
ThIS fIrebOx.
chILDreN AND ADuLTS ShOuLD be ALerTeD TO
The hAzArDS Of hIgh SurfAce TeMperATure
AND ShOuLD STAy AwAy TO AvOID burNS Or
cLOThINg IgNITION.
yOuNg chILDreN ShOuLD be cArefuLLy Super-
vISeD wheN They Are IN The SAMe rOOM AS The
fIrebOx.

INSTALLATION INSTrucTIONS

AND OwNer'S MANuAL
Installer:
consumer:
wArNINg: Improper installation, adjustment, alteration,
service or maintenance can cause injury or property dam-
age. refer to this manual. for assistance or additional in-
formation, consult a qualified installer, service agency or the
gas supplier.
carefully review the instructions supplied with the decora-
tive type unvented room heater for the minimum fireplace
size requirement.
DO NOT INSTALL A veNT-free LOg SeT IN ThIS
fIrebOx, uNLeSS ThIS fIrebOx MeeTS The
MINIMuM DIMeNSIONS reQuIreD fOr The
INSTALLATION.
uNIverSAL fIrebOx fOr ALL
veNT-free LOg SeTS
MODeLS
VFP32FB2DL-3 VFP36FB2DL-3 VFP42FB2DL-3
VFP32FB2CL-2 VFP36FB2CL-2 VFP42FB2CL-2
VFP32FB2EL-2
VFP36FB2EL-2
VFP32FB2DF-3 VFP36FB2DF-3 VFP42FB2DF-3
VFP32FB2CF-2
VFP36FB2CF-2
VFP32FB2EF-2
VFP36FB2EF-2
GAS-FIRED
Leave this manual with the appliance.
retain this manual for future reference.
fOr uSe ONLy wITh A LISTeD gAS-fIreD uN-
veNTeD DecOrATIve rOOM heATer NOT TO
exceeD 40,000 bTu/h.
DO NOT buILD A wOOD fIre.
VFP42FB2EL-2
VFP42FB2CF-2
VFP42FB2EF-2
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VFP32FB2DL-3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Empire Comfort Systems VFP32FB2DL-3

  • Page 1: Installation Instructions

    INSTALLATION INSTrucTIONS AND OwNer'S MANuAL uNIverSAL fIrebOx fOr ALL veNT-free LOg SeTS The Breckenridge Premium Vent-Free Universal Fireboxes MODeLS VFP32FB2DL-3 VFP36FB2DL-3 VFP42FB2DL-3 VFP32FB2CL-2 VFP36FB2CL-2 VFP42FB2CL-2 VFP32FB2EL-2 VFP36FB2EL-2 VFP42FB2EL-2 VFP32FB2DF-3 VFP36FB2DF-3 VFP42FB2DF-3 VFP32FB2CF-2 VFP36FB2CF-2 VFP42FB2CF-2 VFP32FB2EF-2 VFP36FB2EF-2 VFP42FB2EF-2 GAS-FIRED ANSI z21.91 ventless fireplace enclosures for gas fired Dec-...
  • Page 2: Table Of Contents

    TaBLE oF ConTEnTS SECTion PagE important Safety information ....................3 introduction ..........................3 Clearances .......................... 4-5 Firebox installation instructions ..................6-8 installing Hood ........................8-9 gas Line Connection ......................9 optional Fresh air Kit installation instructions ............. 10-12 optional Single Speed Blower installations instructions ..........13-15 Junction Box Wiring installation instructions ..............16 Maintenance .........................16 Parts List ........................
  • Page 3: Important Safety Information

    This Empire Comfort Systems, Inc. firebox and its - Installation other than as instructed by Empire components have been tested and will operate safely when comfort Systems, Inc.
  • Page 4: Clearances

    CLEaRanCES Sidewall clearances: The clearance from the inside of the firebox COMBUSTIBLE to perpendicular combustible side wall should not be less than FINISHED WALL 2 X 4 OR MANTEL 6". See figure 1. HEADER Firebox Side and Back Clearances: The firebox outer casing side and back flanges are zero clearance to combustibles. FINISH WITH TRIM KIT OR Top framing and finishing: Combustible framing may rest on NON-COMBUSTIBLE MATERIAL top of standoffs. Combustible finishing materials may extend STAND OFF...
  • Page 5 CLEaRanCES ceiling clearances: The ceiling height should not be less than 42" from the top of the hood. See Figures 3a and 3b. Mantel clearances: Vent free firebox models must use the hood supplied with the firebox, or one of the optional hood kits available for each model. if a combustible mantel is installed, it must meet the clearance requirements detailed below. grate clearance: The minimum clearance between the front legs of the grate and front edge of the firebox is 2".
  • Page 6: Firebox Installation Instructions

    FiREBoX inSTaLLaTion inSTRUCTionS any vent-free gas Log Heater must be “For use with approved at this point, you should have decided what components to include anSi Z21.11.2 unvented room heater.” in your installation, and where the firebox is to be located. If this has not been done, stop and consult your dealer for assistance with Follow and complete the installation instructions of the gas log set this planning.
  • Page 7 FiREBoX inSTaLLaTion inSTRUCTionS (continued) PREMIUM PREMIUM LOUVERED FLUSH preMIuM LOuvereD fLuSh vfp32 vfp36 vfp42 vfp32 vfp36 vfp42 41 1/8” 41 1/8” 41 1/8” 41 1/8” 41 1/8” 41 1/8” 34 1/2” 39 1/2” 43 1/2” 34 1/2” 39 1/2” 43 1/2” 21 7/16”...
  • Page 8: Installing Hood

    FiREBoX inSTaLLaTion inSTRUCTionS (continued) Locating Firebox Place firebox in framing opening. Use the four (4) framing brackets provided on the firebox to attach firebox to framing. Different hole locations can be used for finishing materials with thicknesses of 3/8", 1/2" and 3/4". Attach these materials with screws provided, two (2) per framing bracket. See figure 8. Framing brackets should fit directly against framing material. Use at least one (1) nail per bracket to secure in place. Check squareness of the firebox prior to securing to framed opening. See figure 9. FIREBOX OPENING ATTACH (4) FRAMING BRACKETS CHECK TO SEE TO SIDES OF FIREBOX THAT BOX IS SQUARE...
  • Page 9: Gas Line Connection

    inSTaLLing HooD (continued) extended hoods If your non-combustible facing material is over 1" in thickness that will be used to finish this firebox, an extended hood is available that will extend out 2" farther out into the room. Contact your local dealer for details. VB4H32BL Standard Black VB4H36BL Standard Black VB4H42BL Standard Black VB4H32BR Polished Brass VB4H36BR Polished Brass VB4H42BR Polished Brass VB4H32SS Stainless Steel VB4H36SS Stainless Steel VB4H42SS Stainless Steel VB4H32HP Hammered Pewter VB4H36HP Hammered Pewter VB4H42HP Hammered Pewter finishing...
  • Page 10: Optional Fresh Air Kit Installation Instructions

    oPTionaL FRESH aiR KiT inSTaLLaTion inSTRUCTionS FoR DELUXE anD PREMiUM FiREBoXES The optional BVa1 Fresh air Kit is designed to introduce outside air to the fireplace or firebox as desired. It must be installed prior to, or at the time of fireplace or firebox installation to framing. The Fresh air kit must be installed prior to the installation of wall- board or other finishing materials around the unit.
  • Page 11 with the hole in the front flange of the movable air door. See when rotated upward, and can be locked open by pulling for- figure 18. ward into the notch at the top of the control lever bracket. 10. To close, simply disengage by letting the lever rotate down- ward. The air door will remain closed by magnetic action. See figure 21.
  • Page 12 completion of Air Kit installation 1. Determine the length of 4” Dia. rigid or flex duct connector OUTSIDE PLATE/VENT (installer supplied) you will need from the firebox/fireplace SCREEN ASSEMBLY AIR DOOR to the exterior surface of the outside wall, where the air kit ASSEMBLY hood will be installed. add a few extra inches to the length to allow for easier attachment of the outside duct connection prior to securing the outside rain cap hood to the building.
  • Page 13: Optional Single Speed Blower Installations Instructions

    oPTionaL SingLE SPEED BLoWER inSTaLLaTion inSTRUCTionS Attention: install blower assembly before connecting gas inlet a factory installed junction box is located on the lower right supply line. side of the firebox. Wiring must be fed to the junction box wiring and attached to the receptacle that is provided. From right The appliance, when installed, must be electrically grounded in side of the firebox, remove the screw securing the junction accordance with local codes or, in the absence of local codes, box assembly.
  • Page 14 4. Insert blower assembly into interior, bottom of firebox. Posi- 8. one fan control wire will have a 1/4” female terminal that tion blower assembly so that you align the notch on back of must be attached to the open terminal on the blower motor. blower assembly with the center screw on firebox back, then See figure 32, connection A. push the blower assembly against firebox back. The blower 9.
  • Page 15 blower Motor 110 VOLT AC JUNCTION BOX The blower motor does not have oiling holes. Do not attempt to oil the blower motor. FAN/MOTOR ASSEMBLY blower wheels The blower wheels will collect lint and could require periodic cleaning. if the air output decreases or the noise level increases, it indicates a dirty blower wheel.
  • Page 16: Junction Box Wiring Installation Instructions

    JUnCTion BoX WiRing inSTaLLaTion inSTRUCTionS cAuTION: ALL wIrINg ShOuLD be DONe by A QuALIfIeD eLecTrIcIAN AND ShALL be IN cOMpLIANce wITh ALL LOcAL, cITy AND STATe buILDINg cODeS. befOre MAKINg The eLecTrIcAL cONNecTION, MAKe Sure ThAT MAIN pOwer SuppLy IS DIScONNecTeD. The AppLIANce, wheN INSTALLeD, MuST be eLecTrIcALLy grOuNDeD IN AccOrDANce wITh LOcAL cODeS Or, IN The AbSeNce Of LOcAL cODeS, wITh The NATIONAL eLecTrIcAL cODe ANSI/NfpA 70 (LATeST eDITION) a factory installed junction box is located on the lower right...
  • Page 17: Parts List

    PaRTS LiST pArT NuMber INDex DeScrIpTION vfp32fb2DL vfp32fb2eL vfp32fb2cL vfp32fb2Df vfp32fb2ef vfp32fb2cf 17247 17247 17247 17247 17247 17247 ToP STanDoFF 17169 17169 17169 UPPER LoUVER 10554 10554 10554 10554 10554 10554 FRaMing BRaCKET 17170 17170 17170 LoWER LoUVER 17162 17162 17162 17162 17162...
  • Page 18: How To Order Repair Parts

    PaRTS LiST pArT NuMber INDex DeScrIpTION vfp42fb2DL vfp42fb2eL vfp42fb2cL vfp42fb2Df vfp42fb2ef vfp42fb2cf 17247 17247 17247 17247 17247 17247 ToP STanDoFF 17187 17187 17187 UPPER LoUVER 10554 10554 10554 10554 10554 10554 FRaMing BRaCKET 17188 17188 17188 LoWER LoUVER 17162 17162 17162 17162 17162...
  • Page 19: Parts View

    PaRTS ViEW 25231-0-0109 Page 19...
  • Page 20: Accessories

    aCCESSoRiES Accessory Description Model Numbers fan Kit Designed to provide forced air flow. FBB5 Variable Speed Control Kit Wall mounted variable speed control for use with SCV-1 FBB5 blower fresh Air Kit Deluxe and Premium Fireboxes BVa-1 frame Kits Standard 3-Piece Frame Kits Black, Brass, Stainless Steel, or Hammered Pewter Contact dealer for all available optional frame kits Extruded aluminum Frame Kits...
  • Page 21 aCCESSoRiES (continued) extended 4" hoods Extended hoods that extend out 2" farther than the standard hoods, to accommodate thicker surround materials. Contact dealer for all available optional hood accessories available as optional kits in Black, Brass, Hammered Pew- ter, and Stainless Steel finishes. Louvers Styles include Slat, Mission, arch, and Leaf Patterns. Contact dealer for all available available as optional kits in Black, Brass, Hammered Pew- optional louver accessories ter, and Stainless Steel finishes.
  • Page 22: Service Notes

    ServIce NOTeS Page 22 25231-0-0109...
  • Page 23: Service Notes

    ServIce NOTeS 25231-0-0109 Page 23...
  • Page 24 Empire Comfort Systems inc. EMPIRE EMPIRE 918 Freeburg ave. Belleville, iL 62220 if you have a general question about our products, please e-mail us at info@empirecomfort.com. if you have a service or repair question, please contact your dealer. Comfort Systems www.empirecomfort.com...

Table of Contents